3.2.1. Locating the unit<br />

-- If possible install unit in such a manner that the compressor<br />

fan can draw fresh air from outside, for instance through an<br />

opening in the wall as low as possible.<br />

-- Ensure that an adequate exhaust air opening is provided,<br />

as high as possible.<br />

-- Locate compressor as close to the air intake opening as<br />

possible. (Minimum distance approx. 50 cm)<br />

-- Locate unit so as to absolutely avoid intake of warm or hot<br />

cooling air.<br />

-- Observe the minimum distances as listed in the table overleaf<br />

(Fig. 11).<br />

3.2.2. Cooling air duct installation<br />

On all Verticus 5 units the cooling air outlet can be installed as<br />

standard in two different ways. By simply removing the air outlet<br />

cover and grid and mounting them in the desired position, the<br />

air outlet can either be on top or on the back of the unit (Fig. 10).<br />

If the outlet on the top is selected, the unit can be positioned<br />

close to a wall, provided a correct air intake according to the following<br />

paragraphs is ensured.<br />

3.2.3. <strong>Air</strong> baffle control (Option)<br />

See drawing 073733 in section F, if applicable. The air circulating<br />

baffles ensure optimal temperature in the compressor room<br />

or at least that the temperature stays within the permissible<br />

range of +5 to +45°C when the outside temperature is low.<br />

The recommended controller thermostat setting is +15 to 18°C.<br />

Adjustment takes place at 4°C above or below the set value.<br />

A temperature sensor in the cooling air intake channeltransmits<br />

to the control unit the temperature of the air taken in. This activates<br />

the actuator of the air circulating baffles. According to requirements,<br />

one of the two baffles in the cooling air exhaust<br />

channel is opened. One guides the warm cooling air to the outside,<br />

the other recirculates the warm cooling air back into the<br />

room. The procedure is continuous and therefore the amount<br />

of warm air being recirculated is continually being adjusted as<br />

necessary.<br />

The cooling air exhaust channel with baffle unit can be connected<br />

to the top or the rear of the VERTICUS 5 unit.<br />

16<br />

NOTE<br />

For further information on the installation of air<br />

cooled compressors, see our Installation <strong>Manual</strong><br />

which can be obtained from BAUER Customer Services,<br />

P.O. 710260, D -81452 Munich<br />

Fig. 9 Locating the unit<br />

Front<br />

side<br />

Fig. 10 Cooling air flow<br />

Operator’s <strong>Manual</strong><br />

Cooling air outlet<br />

standard<br />

optional<br />

Cooling air inlet