3. INSTALLATION, OPERATION<br />
3.1. INSTALLATION OF THE COMPRESSOR UNIT<br />
14<br />
Operator’s <strong>Manual</strong><br />
The compressor frame is equipped with anti--vibration mounts and thus a machine base orspecial means ofsecuring the compressor<br />
are not necessary.<br />
3.1.1. Outdoor location<br />
For installation observe the following:<br />
-- The floor must be capable of taking the load of the system weight.<br />
-- Locate the unit level.<br />
-- On units employing petrol or diesel engine it is most important that only clean air be used. Position compressor in direction of wind<br />
so that exhaust fumes are blown away from the unit. It is good practice to have intake hose of at least 3 m length with pre--filter<br />
and intake filter. Pre--filter to be located 2 m above ground. See Fig. 7. This arrangement will ensure necessary spacing between<br />
exhaust outlet and air inlet.<br />
-- Turn unit as soon as wind direction changes.<br />
-- On petrol or diesel engines, operation unit must only be located outdoors, never indoors, not even in partially closed rooms however<br />
large they may be.<br />
-- Take care that no vehicles with running engines are in direct vicinity.<br />
-- Do not operate unit in the vicinity of open fire (flue gas!). Even cigarette smoke can pollute the breathing air filled in the pressurized<br />
cylinders!<br />
WIND EXHAUST<br />
Fig. 7 Locating air intake hose