3. INSTALLATION, OPERATION<br />

3.1. INSTALLATION OF THE COMPRESSOR UNIT<br />

14<br />

Operator’s <strong>Manual</strong><br />

The compressor frame is equipped with anti--vibration mounts and thus a machine base orspecial means ofsecuring the compressor<br />

are not necessary.<br />

3.1.1. Outdoor location<br />

For installation observe the following:<br />

-- The floor must be capable of taking the load of the system weight.<br />

-- Locate the unit level.<br />

-- On units employing petrol or diesel engine it is most important that only clean air be used. Position compressor in direction of wind<br />

so that exhaust fumes are blown away from the unit. It is good practice to have intake hose of at least 3 m length with pre--filter<br />

and intake filter. Pre--filter to be located 2 m above ground. See Fig. 7. This arrangement will ensure necessary spacing between<br />

exhaust outlet and air inlet.<br />

-- Turn unit as soon as wind direction changes.<br />

-- On petrol or diesel engines, operation unit must only be located outdoors, never indoors, not even in partially closed rooms however<br />

large they may be.<br />

-- Take care that no vehicles with running engines are in direct vicinity.<br />

-- Do not operate unit in the vicinity of open fire (flue gas!). Even cigarette smoke can pollute the breathing air filled in the pressurized<br />

cylinders!<br />

WIND EXHAUST<br />

Fig. 7 Locating air intake hose