Chapter 2: Hardware Installation 2-21<br />

Guidelines for Calibrating the Touch Screen (If Equipped)<br />

The following guidelines should be observed for calibrating the touch<br />

screen.<br />

• Calibration should be done at time of installation.<br />

• <strong>Re</strong>calibrate the touch screen when the system is installed at its final<br />

location.<br />

• <strong>Re</strong>calibrate whenever the terminal is moved to a new location.<br />

• <strong>Re</strong>calibrate the touch screen anytime the system has been<br />

disassembled for servicing.<br />

• Only use the Microcal (DOS) program or the Touchware Control<br />

Panel (Windows) to calibrate the touch screen.<br />

Microcal:<br />

a. Set the video resolution. Go to the Tools menu, Video. Select<br />

800 x 600 256 colors.<br />

b. Go to the Tools menu, select Calibrate.<br />

Touchware Control Panel:<br />

a. Go to the Calibrate tab and press Calibrate.<br />

Calibration Procedure<br />

The calibration program looks at where your finger is when you lift it<br />

off the screen, not where you touch it. Therefore, calibrate the screen as<br />

follows:<br />

1. Touch the screen near the calibration target.<br />

2. Keep your finger on the screen and slide it to the center of the<br />

target.<br />

3. Hold your finger firmly on the target for two seconds, then lift it off<br />

quickly.<br />

4. Verify that the calibration was set accurately before making a<br />

service call. Perform the calibration again if necessary.