2-4 Chapter 2: Hardware Installation<br />
Routing the Cables<br />
The <strong>7455</strong> contains three anchors to secure cables to the base of the unit<br />
using a cable tie wrap. <strong>Re</strong>move the power supply cover from the base<br />
of the unit, which is secured by two screws on the bottom rear. Use a<br />
tie wrap to secure the Ethernet cable to one of the provided molded<br />
cable tie holders on the base. This should provide sufficient strain relief<br />
to prevent the cable from becoming tight and damaging the connector<br />
on the Processor Board.<br />
The peripheral cables are routed down through the Mount Assembly<br />
and out the rear of the unit.<br />