SILANE CROSS-LINKED POLYETHYLENE PIPE<br />

5.1 - Technical data of <strong>INTERSOL</strong> ® PEX-b<br />

Table 3<br />

Mechanical properties Standard Unit Value<br />

Specific gravity DIN 53479 gr/cm 3 0,95<br />

Tensile strength (20°C) DIN 53455 MPa 22 - 27<br />

Elongation at break (20°C) DIN 53455 % 350 - 550<br />

Tensile modulus of elasticity (20°C) DIN 53457 MPa > 550<br />

Impact strength (20°C) DIN 53453 KJ/m 2 No breakage<br />

Moisture absorption (100°C) DIN 53472 % 0,05<br />

Thermal properties<br />

Operating temperature - °C -100 / +100<br />

Softening point - °C 125<br />

Coefficient of linear expansion (20°C) - °C -1 1,4*10 -4<br />

Coefficient of linear expansion (100°C) - °C -1 2,0*10 -4<br />

Impact strength (20°C) - KJ/Kg°C 2,0<br />

Moisture absorption (100°C) DIN 52612 W/m°C 0,35 - 0,41<br />

Electrical properties<br />

Specific internal resistance (20°C) - m 10 15<br />

Dielectric constant (20°C) - - 2,2<br />

Dielectric strength (20°C) - KV/mm 20<br />

9<br />

6 - STANDARD SIZES OF <strong>INTERSOL</strong> ® PEX-b<br />

Standard <strong>pipe</strong> dimensions depend on the field of application and typical standards of each nation.<br />

Above all, distinction can be made between two sectors, namely:<br />

-Floor heating and connection of radiators<br />

-Plumbing systems<br />

6.1 - Floor heating and connection of radiators<br />

Two types of <strong>pipe</strong> can be used, namely:<br />

a) with oxygen diffusion barrier, consisting of a film of coextruded ethylene vinyl alcohol (EVOH)<br />

Table 4<br />

O.D. - for wall thickness Typical Countries Weight (Kg/m) Capacity (l/m)<br />

14 x 2 DD Germany 0,083 0,074<br />

16 x 2 DD Italy 0,097 0,109<br />

17 x 2 DD Germany 0,102 0,126<br />

18 x 2 DD Italy 0,109 0,148<br />

20 x 2 DD Italy - Germany 0,122 0,193<br />

Standard length: 100 - 120 - 200 - 240 metres<br />

b) without anti-oxygen barrier<br />

Table 5<br />

O.D. - for wall thickness Typical Countries Weight (Kg/m) Capacity (l/m)<br />

12 x 2 Italy 0,065 0,048<br />

16 x 2 Italy 0,092 0,108<br />

18 x 2 Italy 0,104 0,150<br />

20 x 2 Italy 0,119 0,194<br />

12 x 1,1 France 0,042 0,073<br />

16 x 1,5 France 0,072 0,128<br />

20 x 1,9 France 0,112 0,201<br />

25 x 2,3 France 0,167 0,318<br />

Standard length: 100 - 120 - 200 - 240 metres