SILANE CROSS-LINKED POLYETHYLENE PIPE<br />
5.1 - Technical data of <strong>INTERSOL</strong> ® PEX-b<br />
Table 3<br />
Mechanical properties Standard Unit Value<br />
Specific gravity DIN 53479 gr/cm 3 0,95<br />
Tensile strength (20°C) DIN 53455 MPa 22 - 27<br />
Elongation at break (20°C) DIN 53455 % 350 - 550<br />
Tensile modulus of elasticity (20°C) DIN 53457 MPa > 550<br />
Impact strength (20°C) DIN 53453 KJ/m 2 No breakage<br />
Moisture absorption (100°C) DIN 53472 % 0,05<br />
Thermal properties<br />
Operating temperature - °C -100 / +100<br />
Softening point - °C 125<br />
Coefficient of linear expansion (20°C) - °C -1 1,4*10 -4<br />
Coefficient of linear expansion (100°C) - °C -1 2,0*10 -4<br />
Impact strength (20°C) - KJ/Kg°C 2,0<br />
Moisture absorption (100°C) DIN 52612 W/m°C 0,35 - 0,41<br />
Electrical properties<br />
Specific internal resistance (20°C) - m 10 15<br />
Dielectric constant (20°C) - - 2,2<br />
Dielectric strength (20°C) - KV/mm 20<br />
9<br />
6 - STANDARD SIZES OF <strong>INTERSOL</strong> ® PEX-b<br />
Standard <strong>pipe</strong> dimensions depend on the field of application and typical standards of each nation.<br />
Above all, distinction can be made between two sectors, namely:<br />
-Floor heating and connection of radiators<br />
-Plumbing systems<br />
6.1 - Floor heating and connection of radiators<br />
Two types of <strong>pipe</strong> can be used, namely:<br />
a) with oxygen diffusion barrier, consisting of a film of coextruded ethylene vinyl alcohol (EVOH)<br />
Table 4<br />
O.D. - for wall thickness Typical Countries Weight (Kg/m) Capacity (l/m)<br />
14 x 2 DD Germany 0,083 0,074<br />
16 x 2 DD Italy 0,097 0,109<br />
17 x 2 DD Germany 0,102 0,126<br />
18 x 2 DD Italy 0,109 0,148<br />
20 x 2 DD Italy - Germany 0,122 0,193<br />
Standard length: 100 - 120 - 200 - 240 metres<br />
b) without anti-oxygen barrier<br />
Table 5<br />
O.D. - for wall thickness Typical Countries Weight (Kg/m) Capacity (l/m)<br />
12 x 2 Italy 0,065 0,048<br />
16 x 2 Italy 0,092 0,108<br />
18 x 2 Italy 0,104 0,150<br />
20 x 2 Italy 0,119 0,194<br />
12 x 1,1 France 0,042 0,073<br />
16 x 1,5 France 0,072 0,128<br />
20 x 1,9 France 0,112 0,201<br />
25 x 2,3 France 0,167 0,318<br />
Standard length: 100 - 120 - 200 - 240 metres