Silane cross-linked polyethylene pipe INTERSOL ... - Watts Industries
Silane cross-linked polyethylene pipe INTERSOL ... - Watts Industries
Silane cross-linked polyethylene pipe INTERSOL ... - Watts Industries
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
SILANE CROSS-LINKED POLYETHYLENE PIPE<br />
6.2 - Plumbing systems<br />
10<br />
Table 6<br />
Dimensions - For wall thickness Typical Countries Weight (Kg/m) Capacity (l/m)<br />
12 x 2 Italy 0,065 0,048<br />
15 x 2,5 Italy 0,100 0,076<br />
18 x 2,5 Italy 0,124 0,127<br />
22 x 3 Italy 0,181 0,193<br />
28 x 3 Italy 0,231 0,376<br />
32 x 3 Italy 0,274 0,521<br />
16 x 2,2 Germany 0,098 0,102<br />
20 x 2,8 Germany 0,153 0,156<br />
25 x 3,5 Germany 0,233 0,251<br />
32 x 4,4 Germany 0,382 0,410<br />
12 x 1,1 France 0,042 0,073<br />
16 x 1,5 France 0,072 0,128<br />
20 x 1,9 France 0,112 0,201<br />
25 x 2,3 France 0,167 0,318<br />
Standard length: 50 - 75 - 100 metres<br />
7 - STANDARDS AND RECOMMENDATIONS<br />
Table 7<br />
GERMANY<br />
STANDARD<br />
Heating<br />
system<br />
Plumbing<br />
system<br />
DIN 16892 Pipes made from high density, <strong>cross</strong>-<strong>linked</strong> <strong>polyethylene</strong> (VPE), X X<br />
general requirements, testing.<br />
DIN 16893 Pipes made from <strong>cross</strong>-<strong>linked</strong> <strong>polyethylene</strong> (VPE), dimensions. X X<br />
DIN 4726 Plastic <strong>pipe</strong>s used in hot water floor heating systems, X<br />
general requirements.<br />
DIN 4729 (*) High density, <strong>cross</strong>-<strong>linked</strong> <strong>polyethylene</strong> <strong>pipe</strong>s for use in hot water floor X<br />
heating systems, general requirements and testing<br />
DIN 4725 Hot water floor heating systems; X<br />
thermal tests (design)<br />
DIN 8076/1 Fittings for floor heating systems X<br />
DIN 1988 + KTW Code of practice for drinking water supply systems X<br />
DVGW - W531 Manufacture, safety and testing of <strong>cross</strong>-<strong>linked</strong> <strong>polyethylene</strong> <strong>pipe</strong>s<br />
(HDPE) for drinking water in home installations<br />
X<br />
DVGW - W532 Metal fittings for <strong>cross</strong>-<strong>linked</strong> <strong>polyethylene</strong> <strong>pipe</strong>s (HPDE)<br />
used in drinking water installations<br />
X<br />
(*) related to and cited in DIN 4726.<br />
Table 8<br />
ITALY<br />
STANDARD<br />
Heating<br />
system<br />
Plumbing<br />
system<br />
UNI 9338 High density, <strong>cross</strong>-<strong>linked</strong> <strong>polyethylene</strong> <strong>pipe</strong>s (VPE), X X<br />
general requirements, testing.<br />
UNI 9349 Cross-<strong>linked</strong> <strong>polyethylene</strong> <strong>pipe</strong>s (VPE), dimensions. X X<br />
Recommendation Plastic <strong>pipe</strong>s used in hot water floor heating systems, X X<br />
IIP n°16<br />
general requirements.