Section 3.4.2 - Underground Dry<br />

Detention Pond<br />

1. “Covenants for Permanent Maintenance <strong>of</strong> Stormwater Management<br />

Facilities” (also<br />

called the “Maintenance Covenants”). An example covenants document<br />

can be found in<br />

<strong>Volume</strong> 3.<br />

2. “Inspection Checklist and Maintenancee Guidance”<br />

for each type <strong>of</strong> stormwater facility<br />

that<br />

is located on the property. Templates for each stormwater management facility can be<br />

found in <strong>Volume</strong> 3 <strong>of</strong> this manual. These templates can be amended slightly for use in<br />

more customized O&M plans.<br />

3. As-builclearly identify reserves and access easements.<br />

All stormwater management facilities must<br />

be maintained in accordance with the O&M Plan.<br />

3.4.2.4 Example Schematics<br />

drawings must accurately identify the layout and location <strong>of</strong> the facility, and<br />

also<br />

Pipe<br />

Pipe<br />

Figure 3-54<br />

Example Underground Detention Tank System<br />

Page 3 - 190<br />

<strong>Volume</strong> 2, Technical Guidance