Section 3.4.1 - Conventional Dry Detention Pond<br />

design is based on the elevation required to pass the 100-year flow with no discharge<br />

through the principal spillway.<br />

• Please refer to “Stormwater Pond”, Section 3.2.1, for additional requirements applicable to<br />

all surface detention ponds.<br />

3.4.1.3 Inspection and Maintenance Requirements<br />

Regular inspection and maintenance is critical to the effective operation <strong>of</strong> stormwater<br />

management facilities. An operation and maintenance plan is required and shall include:<br />

1. “Covenants for Permanent Maintenance <strong>of</strong> Stormwater Management Facilities” (also<br />

called the “Maintenance Covenants”). An example covenants document can be found in<br />

<strong>Volume</strong> 3.<br />

2. “Inspection Checklist and Maintenance Guidance” for each type <strong>of</strong> stormwater facility that<br />

is located on the property. Templates for each stormwater management facility can be<br />

found in <strong>Volume</strong> 3 <strong>of</strong> this manual. These templates can be amended slightly for use in<br />

more customized O&M plans.<br />

3. As-built drawings must accurately identify the location and layout <strong>of</strong> the pond, and also<br />

clearly identify drainage and access easements.<br />

All stormwater management facilities must be maintained in accordance with the O&M Plan.<br />