Section 3.3.1 - Proprietary Treatment Systems<br />
• The study must be conducted in the field, as opposed to laboratory testing;<br />
• Field monitoring must be conducted using standard protocols which require proportional<br />
sampling both upstream and downstream <strong>of</strong> the device;<br />
• Concentrations reported in the study must be flow-weighted; and,<br />
• The propriety system or device must have been in place for at least one year at the time <strong>of</strong><br />
monitoring.<br />
Although local data is preferred, data from other regions can be accepted as long as the<br />
design accounts for the local conditions.<br />
3.3.1.3 Other Requirements<br />
• The local jurisdiction may require that the facility be placed in a reserve and/or<br />
establishment <strong>of</strong> a drainage easement the facility, which is accessible from a public road<br />
or other accessible easement. When required, the drainage easement should be at least<br />
20 feet wide, provide a minimum traversable width <strong>of</strong> 15 feet, have a maximum slope <strong>of</strong> no<br />
more than 10%, and be appropriately stabilized to withstand maintenance equipment and<br />
vehicles.<br />
3.3.1.4 Inspection and Maintenance Requirements<br />
Regular inspection and maintenance is critical to the effective operation <strong>of</strong> stormwater<br />
management facilities. An operation and maintenance plan is required and shall include:<br />
1. “Covenants for Permanent Maintenance <strong>of</strong> Stormwater Management Facilities” (also<br />
called the “Maintenance Covenants”). An example covenants document can be found in<br />
<strong>Volume</strong> 3.<br />
2. “Inspection Checklist and Maintenance Guidance” for each type <strong>of</strong> stormwater facility that<br />
is located on the property. Detailed inspection and maintenance guidance must be<br />
prepared by the manufacturer or design engineer.<br />
3. As-built drawings must accurately show the location <strong>of</strong> the facility, and clearly identify<br />
reserves and access easements.<br />
All stormwater management facilities must be maintained in accordance with the O&M Plan.<br />