Section 3.3.1 - Proprietary Treatment Systems<br />

3.3.1 Proprietary Treatment Systems Secondary Water Quality Facility<br />

Description: Manufactured structural control systems<br />

available from commercial vendors designed to treat<br />

stormwater run<strong>of</strong>f.<br />

Example <strong>of</strong> a manhole media filtration system (Park<br />

Environmental Equipment)<br />

KEY CONSIDERATIONS<br />

DESIGN CRITERIA:<br />

• Independent performance data must be available to prove<br />

a demonstrated capability <strong>of</strong> meeting claimed TSS<br />

removal performance<br />

• System or device must be appropriate for use in<br />

Sedgwick County, Kansas conditions<br />

ADVANTAGES / BENEFITS:<br />

• Typically small space requirement<br />

• Can <strong>of</strong>ten remove coarse sediments well<br />

DISADVANTAGES / LIMITATIONS:<br />

• Depending on the proprietary system, there may be:<br />

• Limited performance data;<br />

• Application constraints such as poor removal <strong>of</strong> fine<br />

sediment;<br />

• High maintenance requirements;<br />

• Higher costs than other structural control alternatives.<br />

• Installation and operations/maintenance requirements<br />

must be understood by all parties approving, owning,<br />

using and maintaining the system or device in question<br />

STORMWATER MANAGEMENT<br />

SUITABILITY<br />

Water Quality Protection<br />

Channel Protection<br />

On-Site Flood Control<br />

Downstream<br />

IMPLEMENTATION CONSIDERATIONS<br />

L<br />

H<br />

H<br />

Land Requirements<br />

Relative Capital Costs<br />

Maintenance Burden<br />

Residential Subdivision Use: Depends<br />

on the specific proprietary structural<br />

control<br />

High Density/Ultra-Urban: Yes<br />

Drainage Area: Depends on the specific<br />

proprietary structural control<br />

Soils: No restrictions<br />

L=Low M=Moderate H=High<br />

Note: It is the policy <strong>of</strong> this Manual not to recommend any specific commercial vendors for proprietary systems.<br />

However, this section is being included in order to provide a base rationale for approving the use <strong>of</strong> a proprietary<br />

system or practice.<br />

<strong>Volume</strong> 2, Technical Guidance Page 3 - 147