Energy Measurement and Management<br />

<strong>P2CBT</strong><br />

Communicator


<strong>P2CBT</strong><br />

The <strong>P2CBT</strong> communicator is intended for remote readout of electricity meters on the level of industrial consumption. It enables bi-directional<br />

data transmission from the meter to the centre and vice versa. The communicator can be connected both to electronic multifunction meters<br />

and industrial meters with a tariff device. The communicator is equipped with RS232, RS485 and CS communication interfaces for connection<br />

with the meter, and PSTN, ISDN and GSM modems for connection with the centre for data collection. Data transmission is performed in<br />

compliance with the EN 61107 protocol (mode A, B, C or D) or the IEC 870–5–102 protocol (Din 19244 Slave).<br />

Communicator functions<br />

The communicator is a programmable, processor-supported device where parameters can be set locally via an<br />

optical interface or remotely via a modem. A Poreg2View program is used for setting parameters of communicator<br />

operation (made by <strong>Iskraemeco</strong>) or an optional terminal program can be used.<br />

The communicator enables the following functions:<br />

– Acquisition of measuring data via various communication interfaces<br />

– Storing of read billing data in a permanent memory (a load curve cannot be stored!)<br />

– Data conversion from the EN61107 protocol to the IEC 870-5-102 protocol (DIN 19244 Slave)<br />

– Relaying of read measuring data via a modem to a centre<br />

– Multi-level data protection<br />

– Management of real time and related time function<br />

– Monitoring of operation and management of a log book<br />

– Supervision of a built-in modem operation<br />

It is possible to connect simultaneously 1 meter to the RS232 channel, 4 meters to the CS – 20 mA current loop,<br />

and 31 meters to the RS485 channel. Each meter should be provided with a unique identification number.<br />

Although up to 36 meters can be connected to one communicator at the same time, data transfer can be performed<br />

only from one meter at a time! If the CS channel is not used, short-circuit connection is required!<br />

Operation<br />

The communicator supports three<br />

modes of data transmission, and at<br />

the same time also provides for<br />

data security and supervision of the<br />

modem operation.<br />

IEC 1107 MASTER<br />

Data transmission between the<br />

meter and the communicator is<br />

performed in compliance with the<br />

EN 61107 protocol (A,B,C and D<br />

modes are supported), and<br />

between the communicator and the<br />

centre for data collection in compliance<br />

with the IEC 870-5-102<br />

protocol (Din 19244 Slave). Data<br />

reading can be activated remotely<br />

from the centre, automatically with<br />

adjustable time period or by pressing<br />

a special key on the meter.<br />

Readout data can be stored in the<br />

communicator or they can be<br />

transmitted directly into the centre.<br />

Capacity of the internal memory in<br />

the communicator does not enable<br />

storing of load profile data!<br />

CASCADE<br />

It is intended for transparent meter<br />

readout in compliance with the<br />

EN 61107 standard, C mode, without<br />

rate change over. A request for<br />

reading a certain meter received by<br />

the communicator on a modem<br />

channel is transparently transmitted<br />

via all communication channels to<br />

all meters. The meter with a corresponding<br />

identification number<br />

answers to the request and establishes<br />

connection with the centre.<br />

Data transmission rate should be<br />

fixed and the same at all meters.<br />

EN61107 CASCADE<br />

It is intended for transparent meter<br />

readout in compliance with the<br />

EN 61107 standard, C mode, with<br />

rate changeover. Data transmission<br />

is performed in the same way as in<br />

CASCADE, only that the communicator<br />

receives the request at an<br />

optional rate (usually 9600 Bps),<br />

converts it to 300 Bps and sends it<br />

to the meters. A corresponding<br />

meter answers to 300 Bps about the<br />

rate it requires for communication.<br />

The communicator transmits the<br />

answer to the centre at the original<br />

rate (usually 9600 Bps). Communication<br />

is then performed with the<br />

rate that is set in the meter.<br />

DATA SECURITY<br />

Data as well as parameters that are<br />

stored in the internal memory are<br />

protected with three protection<br />

codes (a device code, a user code<br />

and a user password). All three<br />

codes are required for connection<br />

with a communicator. Up to eight<br />

users with different rights (data<br />

reading, parameter changing, etc.)<br />

that have the access to the communicator<br />

can be defined.<br />

The access to the meters can be<br />

protected also with the a password<br />

in a transparent or a cascade mode<br />

of operation. Two protection modes<br />

are supported in the communicator;<br />

at both of them a cascade channel<br />

opens only if a corresponding<br />

password is known.<br />

SUPPORT FOR GSM MODEM<br />

A Central processing unit (CPU)<br />

permanently monitors a GSM<br />

modem operation. After connection<br />

to supply voltage, it provides for<br />

correct GSM module switch-on, it<br />

writes PIN and PUK codes, selects<br />

the operator and registers itself into<br />

network. CPU then permanently<br />

checks the modem operation and<br />

measures signal strength. If abnormal<br />

operation of the GSM module<br />

is stated, CPU resets it and registers<br />

it again into network in compliance<br />

with the described procedure.<br />

Communicator operation can be<br />

monitored via seven LEDs.


<strong>P2CBT</strong><br />

TECHNICAL DATA<br />

POWER SUPPLY<br />

Supply voltage:<br />

– Single-phase a.c. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85 V – 265 V, 50 Hz<br />

– d.c. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 V – 300 V<br />

Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Max. 5 VA<br />

Auxiliary power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Supercap 1.5F, keeping data and time up to 14 days<br />

SERIAL INTERFACES<br />

Transmission rate Max. line length Max. no. of meters<br />

RS232 300 – 33 400 Bps 15 m 1<br />

CS 300 – 33 400 Bps 1200 m 4<br />

RS485 300 – 33 400 Bps 1200 m 31<br />

COMMUNICATION<br />

Optical interface<br />

Transmission rate . . . . . . . . . . . . .2400 Bps<br />

PSTN V.34 modem Data services . . . . . . . . . . . . . . . .V.34, V.32bis, V.32, V.22bis, V.22, V.23 V.21<br />

Correction of errors . . . . . . . . . . .V.42 LAPM and MNP 2-4<br />

Data compression . . . . . . . . . . . . .V.42bis and MNP 5<br />

Connector . . . . . . . . . . . . . . . . . . .RJ11<br />

ISDN TA<br />

GSM modem<br />

D-channel protocol<br />

X.31 (X.25 in D-Channel<br />

DSS1 (with implemented UUS and Sub-addressing service)<br />

B-channel-protocols<br />

V.110 (1200 – 19200 Bps)<br />

HDLC asynchronous/synchronous conversion – PPP<br />

HDLC transparent transfer<br />

X.75 – data transfer and TA remote control (64 000 bit/s)<br />

V.120<br />

X.31 (X.25 in B-Channel)<br />

ML PPP (recombining of B-Channels) (2 x 64 000 bit/s)<br />

Connector . . . . . . . . . . . . . . . .RJ45<br />

Type . . . . . . . . . . . . . . . . . . . .Siemens TC35i<br />

GSM characteristic . . . . . . . . .Dual band EGSM900 in GSM 1800, GSM phase 2/2+<br />

GSM data services . . . . . . . . .up to 14 400 bps, USSD, non-transparent<br />

V.21, V.22, V.23, V.22bis, V.26ter, V.32, V.34, V.110<br />

SIM cards reader . . . . . . . . . .External, for small SIM cards (5/3V)<br />

Connector . . . . . . . . . . . . . . . .FME<br />

OPERATION CONDITIONS<br />

Ambient temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-25°C to + 60°C<br />

Air humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .max. 75%<br />

Dust protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IP 50 (IEC 529)<br />

DIMENSIONS<br />

Length x Height x Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 mm x 176 mm x 54 mm<br />

Mass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.46 kg<br />

ASSEMBLY<br />

A communicator can be fixed to the meter terminal cover on three spots or independently on the wall.


<strong>P2CBT</strong><br />

CONNECTION DIAGRAM<br />

<strong>P2CBT</strong> with ISDN or PSTN modem<br />

<strong>P2CBT</strong> with GSM modem<br />

RS232<br />

CS RS485<br />

PSTN<br />

ISDN<br />

RS232 CS RS485 GSM<br />

L1<br />

N<br />

L1<br />

N<br />

Rx<br />

Tx<br />

GND<br />

CS+<br />

CS-<br />

A<br />

B<br />

Rx<br />

Tx<br />

GND<br />

CS+<br />

CS-<br />

A<br />

B<br />

1<br />

2<br />

3 4 5<br />

6<br />

7<br />

8<br />

9<br />

10 11<br />

1<br />

2<br />

3 4 5<br />

6<br />

7<br />

8<br />

9<br />

10 11<br />

OVERALL AND FIXING DIMENSIONS<br />

MARKING<br />

<strong>P2CBT</strong> K52 - 07 . . . . . . .IR + RS232 + CS + RS485 + PSTN modem V.34<br />

<strong>P2CBT</strong> K526 - 07 . . . . . .IR + RS232 + CS + RS485 + ISDN TA<br />

<strong>P2CBT</strong> K527 - 07 . . . . . .IR + RS232 + CS + RS485 + GSM modem<br />

55.2 179.0<br />

3.5<br />

100.0<br />

152.0<br />

125.0<br />

Owing to periodical improvements of our products the supplied products can differ in some details from the data stated in the prospectus material.<br />

<strong>Iskraemeco</strong>, Energy Measurement and Management<br />

4000 Kranj, Savska loka 4, Slovenia<br />

Telephone: (+386 4) 206 40 00, Telefax: (+386 4) 206 43 76,<br />

http://www.iskraemeco.si, e-mail: info@iskraemeco.si<br />

Published by <strong>Iskraemeco</strong>. Data subject to alteration without notice.<br />

<strong>Iskraemeco</strong>, Energy Measurement and Management<br />

17th Cleopatra st., Heliopolis, Cairo Egypt<br />

Telephone: (+202) 22909830, Fax: (+202) 24180984,<br />

e-mail: info.iskra@iskraemeco.com.eg<br />

Published by <strong>Iskraemeco</strong>. Data subject to alteration without notice.<br />

722.999.188 0312/61