M<strong>SB</strong>_OpMan_07_us.FM<br />

Korrekturausdruck<br />

7.1.7 Surface ventilation (optional)<br />

7.1 General Technical Data<br />

To increase the permanent motor torque, the <strong>SB</strong> <strong>Motor</strong>s can be<br />

supplied with surface ventilation.<br />

The surface ventilation reduces the thermal transition resistance,<br />

so that the permanent torque characteristics of the motor are<br />

shifted upwards. The peak motor torque is not changed.<br />

The increased permanent torque values are saved in the electronic<br />

type plate of the motor or the motor database.<br />

Fig. 7-4: Example for an <strong>SB</strong> <strong>Motor</strong> with surface ventilation<br />

The fan is dimensioned differently for each motor series:<br />

rated voltage not<br />

available<br />

power intake not<br />

available<br />

fan<br />

<strong>SB</strong> 056 <strong>SB</strong> 070 <strong>SB</strong> 105 <strong>SB</strong> 145 <strong>SB</strong> 205 Einheit<br />

Table 7-8: Technical data of the fans<br />

230 230 230 400 V<br />

3 AC<br />

ca. 0,08 ca. 0,13 ca. 0,23 ca. 0,15 [A]<br />

[V] AC<br />