7 Technical Data<br />
NOTE<br />
There are only a few diagnosis messages of the <strong>Motor</strong>Controller<br />
(MC-4 diagnosis messages with reaction A) which do not permit a<br />
controlled stop of the motor. In these few cases, the holding brake<br />
of the motor is required for the complete brake procedure (EMER-<br />
GENCY STOP).<br />
The times are valid for direct current, regular operating temperature<br />
and rated voltage. Separation time is the time from switching on the<br />
power to the point when the torque has faded to 10% of the rated<br />
torque. Connection time is the time from switching off the power<br />
until the rated torque is reached.<br />
CAUTION!<br />
Power loss in case of long cables!<br />
The brake may be worn out or damaged!<br />
� The data for rated power and rated voltage apply at the connection<br />
box. Check the data at the connection box. A higher or separate<br />
power supply of the brake may be necessary. A too high<br />
voltage can also damage the brake!<br />
<strong>SB</strong> 056 <strong>SB</strong> 070 <strong>SB</strong> 105 <strong>SB</strong> 145 <strong>SB</strong> 205 Unit<br />
holding moment 0,8 1,5 5 15 50 [Nm] ([lb-in.])<br />
connection time 80 80 80 80 80 [ms]<br />
separation time 200 200 200 200 200 [ms]<br />
mass 0,8 2 3 5 14 [kg]<br />
moment of inertia 0,17 0,4 0,63 1,95 10 [kgcm 2 ]<br />
([lb-in.-s 2 ])<br />
rated power 0,4 0,6 1,1 1,9 1,7 [W]<br />
rated voltage 24 +/-10% 24 +/-10% 24 +/-10% 24 +/-10% 24 +/-10% [V] DC<br />
Table 7-7: Technical data of the holding brake of the <strong>SB</strong> <strong>Motor</strong><br />
page 58 <strong>SB</strong>-<strong>Motor</strong> PacDrive<br />