BEAM & BLOCK<br />

HOLLOWCORE FLOORS<br />

PRECAST SECTIONS<br />

CONCRETE LINTELS<br />

STEEL LINTELS<br />

<strong>Concrete</strong> <strong>Flooring</strong> <strong>Brochure</strong>


Stressline <strong>Flooring</strong> Systems<br />

Stressline's extensive range of prestressed fl ooring products allows<br />

estimators and designers to determine the most economical solution<br />

to satisfy your loading and span requirements.<br />

Upon receipt of your enquiry, which should contain copies of your<br />

working drawings and loading requirements, Stressline will produce a<br />

detailed quotation for your consideration.<br />

After placing your order Stressline's technical offi ce will design and<br />

prepare a comprehensive layout drawing, which will be sent back<br />

to you for approval to ensure that your requirements have been<br />

covered.<br />

Prestressed <strong>Flooring</strong><br />

‘I’ Beam Design<br />

Various Sections<br />

End Slips<br />

Design & Development<br />

Being able to offer both ground and upper fl ooring solutions<br />

incorporating precast stairs, landings and balconies enables the<br />

customer to source all his structural fl ooring requirements from just<br />

one supplier.<br />

Full technical support and advice is available from product<br />

suitability, through to detailed design calculations, all free of charge.<br />

Installation onto masonry or steelwork by our qualifi ed teams of<br />

installers ensures that your fl oor has been installed correctly and that<br />

the designed solution has not been compromised.<br />

Whether you are looking for a ground fl oor for a home extension, or<br />

a major multi call-off development Stressline have a service solution<br />

that will suit your needs.<br />

Prestressed <strong>Concrete</strong><br />

Spans in excess of 9m<br />

150mm & 200mm Deep<br />

Design & Development<br />

Precast Sections<br />

Prestressed Beam and Block <strong>Flooring</strong><br />

Stressline has constantly reacted to changes in modern building<br />

practices and have developed their own range of prestressed<br />

concrete fl oor beams, incorporating either dense concrete blocks<br />

or high grade polystyrene forms able to span up to 8 metres.<br />

Available for use at both ground fl oor, and in certain circumstances<br />

at fi rst fl oor, prestressed beam fl ooring offers a fl exible and<br />

dependable method to overcome diffi cult site conditions.<br />

Architects, engineers and developers have learnt that the Stressline<br />

range of prestressed suspended fl ooring provides the ideal solution where land has been made up, is<br />

sloping, or has potential contamination concerns. With the benefi ts of off-site manufacturing and no on site<br />

curing of concrete, it is possible to allow following trades access as soon as the fl oor is installed.<br />

Hollowcore <strong>Flooring</strong><br />

To compliment the beam fl ooring systems Stressline offer two sections of Hollowcore fl ooring, with spans in<br />

excess of 9 metres, either 150mm deep or 200mm deep to resolve many specifi cation problems.<br />

Precast <strong>Concrete</strong><br />

With Stressline's in-house design and technical team it is possible to produce staircases up to a capacity of<br />

10 tonnes, either straight or cranked together with landing slabs and other precast requirements.<br />

13


<strong>Flooring</strong> Systems<br />

Floor fi nishes to<br />

Architects specifi cation<br />

Hollowcore <strong>Flooring</strong><br />

Provision for<br />

services and pipes<br />

Multiple Beam<br />

support for stair fl ight<br />

Beam Spacings<br />

adjusted to suit<br />

load/span<br />

End Slips allow full<br />

fl oor coverage<br />

of blocks<br />

Staggered Beams<br />

used on shared bearing<br />

D.P.C used<br />

at ground fl oor level<br />

Typical Layout and Construction Details<br />

14


Prestressed <strong>Flooring</strong><br />

Infill Block Specification<br />

Any dimensionally accurate solid building<br />

blocks 440 x 215 x 100mm may be used as infi ll<br />

within the fl oor provided that they can<br />

support a 3.5kN Transverse Load over a 400mm<br />

clear span. Stressline's quotation will specify a<br />

maximum block density that the fl oor has been<br />

designed for. While lighter blocks may be used<br />

on no account should heavier than specifi ed<br />

block be used.<br />

Your Builders Merchant or block manufacturers<br />

will confi rm the suitability of your blocks.<br />

Some aerated concrete block manufacturers<br />

have fl oor infi ll blocks of non-standard size.<br />

These can be incorporated into the fl oor<br />

provided that Stressline are aware of their<br />

probable use at the quotation and design<br />

stage. (Protection of this infi ll will be required<br />

during construction).<br />

<strong>Concrete</strong> Infill<br />

Where infi ll concrete between beams is used<br />

this should be of mix proportion 1:5:3<br />

(Cement/Sand/Aggregate) with maximum<br />

10mm aggregate.<br />

Holes Through The Floor<br />

The formation of the holes will be by the<br />

omission of blocks from the fl oor. Voids around<br />

pipes to be made good with insitu concrete.<br />

DPC/DPM<br />

These are to be provided by others in<br />

accordance with Architect’s details. It is a<br />

NHBC requirement that a DPC should be<br />

installed beneath the fl oor beams to deter<br />

aggressive ground water chemical attack.<br />

This is in addition to the other membranes<br />

which the Architect may specify.<br />

Ventilation<br />

Where the void to the underside of ground<br />

fl oor is to be ventilated, air bricks must be<br />

fi tted to manufacturer’s specifi cations.<br />

Provisions should be made for ventilation<br />

through internal support/sleeper walls.<br />

Ventilation from garages is not permitted.<br />

A minimum of 1500mm² of free air per metre<br />

run of external wall is required. Care must be<br />

exercised when positioning ventilators. Floor<br />

beams must not bear directly onto the<br />

ventilator.<br />

Gas Membrane<br />

Where Methane or Radon gas penetration is<br />

perceived as a potential problem, proprietary<br />

gas proof membranes may be applied across<br />

the fl oor and adjacent walls and cavities so as<br />

to isolate the dwelling from the void beneath.<br />

Additional sub-fl oor ventilation requirements<br />

may need to be met. Local Building Control<br />

should be able to advise on this.<br />

Thermal Insulation<br />

Latest Building Regulations call for ground<br />

fl oors to have thermal performance.<br />

Numerous different calculation routes are<br />

available to determine the amount of<br />

insulation (if any) required to comply with<br />

these requirements. Your Architect/Engineer<br />

should have determined these during your<br />

Building Regulations application.<br />

Void<br />

A minimum void of 75 -100mm is required<br />

beneath the fl oor. This should be doubled on<br />

clay heave sites.<br />

Ceiling<br />

Ceiling clips to support 50 x 38mm ceiling<br />

battens are available if required for upper<br />

fl oors. A minimum ceiling void of 38mm can<br />

provide service runs.<br />

Split Courses<br />

Stressline offer 375 x 90 x 40mm concrete slips<br />

for making good to the edges of the fl oor<br />

where a 50mm split course is required to the<br />

underside of the infi ll blocks. Stressline's<br />

quotation will detail quantities and price for<br />

these edge blocks.<br />

Precast Staircases<br />

Stressline are able to design and manufacture<br />

precast concrete stairs, landing and balconies<br />

to complete your building requirement.<br />

Delivery dates for these precast specials will<br />

be given at enquiry stage.<br />

Please refer to Stressline's Health and Safety<br />

documentation before receiving your delivery.<br />

15


Prestressed ‘I’ Beams<br />

Section Weight Centres Floor Self Weights<br />

Prestressed<br />

Strands<br />

Serviceable<br />

Moment<br />

Ultimate<br />

Moment<br />

Ultimate<br />

Shear<br />

Basic Fire<br />

Resistance<br />

(WxD)mm<br />

(kg/m) (mm) 1900 kg/m³<br />

(kN/m²)<br />

(kg/m²)<br />

1350 kg/m³<br />

(kN/m²)<br />

(kg/m²)<br />

650 kg/m³<br />

(kN/m²)<br />

(kg/m²)<br />

(kNm) (kNm) (kN) (Hours)<br />

510 2.15 219 1.68 171 1.14 116<br />

105 X 150 28.03 510/285 2.23 227 1.78 182 1.27 130<br />

1 x 9.3mm 4.326 6.864 15.870 0.5<br />

285 2.37 242 1.96 200 1.51 154<br />

530 2.19 224 1.75 178 1.22 125<br />

125 X 150 34.95 530/305 2.28 233 1.86 190 1.37 140<br />

2 x 8.0mm 6.676 10.024 24.627 0.5<br />

Designed to BS8110<br />

305 2.44 249 2.06 210 1.63 166<br />

570 2.30 234 1.88 192 1.40 143<br />

165 X 150 50.06 570/345 2.41 245 2.02 206 1.58 161<br />

345 2.58 264 2.25 229 1.87<br />

305 3.13 320 2.75 281 2.27<br />

191<br />

530 2.60 265 2.15 219 1.58 161<br />

125 X 225 56.70 530/305 2.79 285 2.37 242 1.83 187<br />

232<br />

1 x 9.3mm<br />

&<br />

2 x 8.0mm<br />

1 x 9.3mm<br />

&<br />

2 x 8.0mm<br />

9.611 14.727 38.200 0.5<br />

15.800 23.000 32.940 0.5<br />

16


<strong>Flooring</strong> Load Span Tables<br />

Wide Centres - using flooring block<br />

440<br />

Beam<br />

(mm)<br />

105 x 150<br />

125 x 150<br />

165 x 150<br />

125 x 225<br />

Centres<br />

(mm)<br />

510<br />

530<br />

570<br />

530<br />

Superimposed Load in kN/m²<br />

Block Density<br />

(kg/m³) 1.5 2.0 2.5 3.0 4.0 5.0<br />

1900<br />

3.53 3.36 3.22 3.04 2.60 2.27<br />

1350<br />

3.70 3.51 3.35 3.21 2.76 2.39<br />

650<br />

3.99 3.76* 3.56* 3.39*<br />

1900<br />

4.30 4.10 3.93 3.78 3.51 3.28<br />

1350<br />

4.50 4.28 4.08 3.91 3.61 3.37<br />

650<br />

4.83 4.56* 4.33* 4.12*<br />

1900<br />

4.94 4.72 4.52 4.35 4.05 3.81<br />

1350<br />

5.15 4.90 4.68 4.49 4.17 3.91<br />

650<br />

5.49 5.19* 4.94* 4.71*<br />

1900<br />

5.90 5.62 5.37 5.25 4.80 4.50<br />

1350<br />

6.15 5.82 5.55 5.32 4.92 4.60<br />

650<br />

6.50 6.15* 5.82* 5.55*<br />

Maximum clear span in metres<br />

Alternate Centres - using flooring block<br />

440 215<br />

Beam<br />

(mm)<br />

105 x 150<br />

125 x 150<br />

165 x 150<br />

125 x 225<br />

Centres<br />

(mm)<br />

510/285<br />

530/285<br />

570/345<br />

530/305<br />

Block Density<br />

(kg/m³) 1.5<br />

1900<br />

3.98<br />

1350<br />

4.16<br />

650<br />

4.20*<br />

1900<br />

4.82<br />

1350<br />

5.00<br />

650<br />

5.00<br />

1900<br />

5.47<br />

1350<br />

5.68<br />

650<br />

6.02<br />

1900<br />

6.55<br />

1350<br />

6.80<br />

650<br />

7.17<br />

Maximum clear span in metres<br />

Narrow Centres - using flooring block<br />

2.0<br />

3.79<br />

3.96<br />

3.20<br />

4.60<br />

4.78<br />

5.00*<br />

5.23<br />

5.41<br />

5.70*<br />

6.25<br />

6.47<br />

6.77*<br />

Superimposed Load in kN/m²<br />

2.5<br />

3.63<br />

3.78<br />

3.99*<br />

4.41<br />

4.57<br />

4.82*<br />

5.02<br />

5.18<br />

5.43*<br />

6.00<br />

6.17<br />

6.45*<br />

3.0<br />

3.49<br />

3.62<br />

3.81*<br />

4.24<br />

4.38<br />

4.60*<br />

4.83<br />

4.97<br />

5.19*<br />

5.75<br />

5.92<br />

6.17*<br />

4.0<br />

3.25<br />

3.35<br />

5.0<br />

2.92<br />

3.07<br />

3.95 3.70<br />

4.05 3.78<br />

4.51 4.24<br />

4.62 4.34<br />

5.35 5.02<br />

5.50 5.15<br />

215 215 215<br />

Beam<br />

(mm)<br />

105 x 150<br />

125 x 150<br />

165 x 150<br />

125 x 225<br />

Centres<br />

(mm)<br />

285<br />

305<br />

345<br />

305<br />

Superimposed Load in kN/m²<br />

Block Density<br />

(kg/m³) 1.5 2.0 2.5 3.0 4.0 5.0<br />

1900<br />

4.20 4.20 4.20 4.10 3.82 3.60<br />

1350<br />

4.20 4.20 4.20 4.20 3.93 3.68<br />

650<br />

4.20 4.20* 4.20* 4.20*<br />

1900<br />

5.00 5.00 5.00 5.00* 4.59 4.31<br />

1350<br />

5.00 5.00 5.00 5.00 4.70 4.40<br />

650<br />

5.00 5.00* 5.00* 5.00*<br />

1900<br />

6.10 5.95 5.71 5.50 5.15 4.85<br />

1350<br />

6.10 6.10 5.87 5.64 5.26 4.94<br />

650<br />

6.10 6.10* 6.10* 5.85*<br />

1900<br />

7.45 7.12 6.85 6.60 6.15 5.80<br />

1350<br />

7.67 7.32 7.02 6.75 6.30 5.90<br />

650<br />

7.80 7.62* 7.27* 6.97*<br />

Maximum clear span in metres<br />

Notes. 65mm screed fi nish with insulation 1.41 kN/m² has been included.<br />

This table is given as a guide only and allowance should be given to partition loads or point loads supported by fl oor. The effect of<br />

camber and defl ection on partitions must be considered when using maximum or near maximum spans. It is recommended that a<br />

mesh screed for imposed loads in excess of 5.0 kNm² when the block is 440mm. *For superimposed loads other than 1.5 kNm² using<br />

650kg/m³ blocks refer to block manufacturer. Block Size: 440 x 215 x 100mm.<br />

17


<strong>Flooring</strong> Load Span Tables<br />

Standard Centres - using thermal floor<br />

Beam<br />

Width x Depth<br />

(mm)<br />

Centres<br />

(mm)<br />

Superimposed Load<br />

1.5 (kN/m²)<br />

105 x 150 610 3.730<br />

125 x 150 630 4.530<br />

165 x 150 670 5.175<br />

Maximum clear span in metres<br />

*75mm screed fi nish - 1.84 kN/m² has been included.<br />

Note:<br />

The fl oor can withstand a live load of 5kN/m² from blockwork partitions, parallel and perpendicular to the<br />

span. This load is NOT included in our calculations for the above load/span table. Please contact our<br />

technical department for advice.<br />

T60 (540 x 1220) has been used in our calculations.<br />

Prestressed Hollowcore Floor<br />

Unit<br />

Depth<br />

Self Weight<br />

kN/m²<br />

Self Weight<br />

kg/m²<br />

1.5 2.0 2.5 3.0 4.0 5.0 7.50<br />

150H 2.96 302 7.10 6.90 6.65 6.45 6.10 5.80 5.20<br />

200 2.94 300 8.40 8.10Superimposed 7.80 7.60Load 7.10 (kN/m²) 6.75 6.00<br />

Maximum clear span in metres allows for characteristic service live loads + self weight + 1.5 kN/m²<br />

fi nishes + 1kN/m² partitions.<br />

18


End Slips<br />

375 x 90 x 40mm and 375 x 125 x 40mm end slips are specifi cally<br />

designed for use with Stressline fl oor beams.<br />

This slimline block provides a simple and cost effective solution by<br />

allowing standard fl ooring grade infi ll blocks to be used over the entire<br />

fl oor area instead of using more costly infi ll/edge block combination.<br />

The end slips can be easily cut when used with narrow beam<br />

centres.<br />

Stressline end slips can also be used as a coursing block<br />

to adjust fl ooring levels as required.<br />

375 x 90 x 40 mm<br />

Stressline Floor Beam<br />

375 x 125 x 40 mm<br />

Standard ACBA<br />

flooring grade infill<br />

blocks (by others)<br />

Stressline End Slip<br />

D.P.C. (by others)<br />

375 x 90 x 40mm and 375 x 125 x 40mm end slips are specifi cally designed for use with Stressline<br />

fl oor beams.<br />

This slimline block provides a simple and cost effective solution by allowing standard fl ooring grade infi ll<br />

blocks to be used over the entire fl oor area instead of using more costly infi ll/edge block combination.<br />

The end slips can be easily cut when used with narrow beam centres.<br />

END SLIP SECTION DIMENSION<br />

L X W X H mm<br />

(Nominal)<br />

INNER SKIN<br />

(mm)<br />

UNIT WEIGHT<br />

(kg)<br />

PACK QUANTITY<br />

PACK WEIGHT<br />

(kg)<br />

CRUSHING<br />

STRENGTH (N/mm²)<br />

375 x 90 x 40<br />

100<br />

2.85<br />

200<br />

570<br />

35<br />

375 x 125 x 40<br />

125 - 140<br />

4.20<br />

200<br />

840<br />

35<br />

19


Stressline Limited<br />

Foxbank Industrial Estate<br />

Stoney Stanton<br />

Leicester<br />

LE9 4LX<br />

T: 0870 750 3167<br />

F: 0870 750 6379<br />

E: sales@stressline.ltd.uk<br />

The information contained in this brochure was accurate at the date of<br />

publication. We reserve the right to introduce, at any time, modifi cations and<br />

changes of details that may be deemed necessary. December 2009.<br />

www.stressline.ltd.uk