Technical data: Motors<br />

General data / Operating conditions<br />

Standards<br />

Operating mode<br />

Degree of protection<br />

Temperature class<br />

(VDE 0530)<br />

Insulation strength<br />

Temperature monitoring<br />

Temperature range<br />

Installation height<br />

Terminal box<br />

Bearing<br />

Power derating<br />

Effect of the installation height<br />

The motors meet the requirements of applicable DIN and IEC standards.<br />

CE conformance with the low voltage directive<br />

CSA/UL optional<br />

Dimensioned for operating mode S1<br />

(continuous operation with constant load at rated power)<br />

IP 55 (self-ventilated)<br />

Insulation system to temperature class F<br />

Utilization to temperature class B<br />

Maximum voltage amplitude Û = 1.5 kV<br />

Maximum rate of voltage rise du/dt = 5 kV/s<br />

Thermal sensor (NC contact)<br />

-20 to +40°C, no power derating<br />

Up to 1000 m above sea level, no power derating<br />

Motor connection to terminal board, built-on accessories on terminal block,<br />

built-in brake rectifier in terminal box<br />

Deep-groove ball bearing with<br />

high-heat-resistant grease, 2 cover plates<br />

Effect of the ambient operating temperature<br />

3<br />

Effect of the installation height above sea level on the<br />

rated power<br />

H [m] = 1000 2000 3000 4000<br />

P h<br />

P N<br />

1 0.95 0.90 0.85<br />

Effect of the ambient operating temperature<br />

T u on the rated power<br />

T u [ºC] = 40 45 50 55 60<br />

P <br />

P N<br />

1 0.95 0.90 0.85 0.80<br />

Calculation for the power derating P red<br />

Torque reduction<br />

P red = Ph · P · P<br />

P N<br />

N P N<br />

On motors with integral fans, cooling is determined by the<br />

shaft speed, as the integral fan is connected to the motor<br />

shaft. When used in conjunction with the 8200 motec<br />

frequency inverter, the motors can travel through a variable<br />

speed or frequency range. If the output frequency of the<br />

8200 motec is low, the air flow of the integral fan is not<br />

sufficient to dissipate the heat loss occurring in the motor<br />

at the rated torque (M N ). Therefore, the torque (M) that can<br />

be drawn from the motor should be reduced to less than<br />

20 Hz. The following dependence applies to the various<br />

motor frame sizes:<br />

Note: You should also refer to the technical data and ratings for the 8200 motec frequency inverters<br />