Drive design<br />

Required load capacity<br />

Determine the required output torque M 2 and output speed n 2<br />

<br />

2<br />

Calculate the required motor power P1 = M 2 · n 2<br />

9550 · <br />

<br />

Determine the load class:<br />

<br />

Load Load type Intensity<br />

class<br />

I Regular operation, virtually shock-free M I ≤ 1.5<br />

II Irregular operation, moderate shocks 1.5 < M I ≤ 2<br />

III Irregular operation, strong shocks 2 < M I ≤ 2.5<br />

and/or changing loads<br />

<br />

M I =<br />

Determine temporary influences: – Operating time/day, running time at M max in %<br />

M max<br />

M r<br />

<br />

Determine the operating factor k of the machine from the diagram<br />

<br />

Operating time/day<br />

2.4<br />

2.3<br />

2.2<br />

2.2<br />

2.1<br />

2<br />

2<br />

1.9<br />

1.8<br />

Operating factor k<br />

1.8<br />

1.7<br />

1.8<br />

1.6<br />

1.6<br />

1.4<br />

1.5<br />

1.4<br />

1.2<br />

1.3<br />

1.2<br />

1.0<br />

Running time at M max<br />

<br />

Requirement for geared motor: c (selection table) ≥ k<br />