Q28: Question<br />
Scary hospital vascular lab is validating their testing procedure predicting<br />
common carotid artery disease. The following results were obtained relative to<br />
the “gold standard”:<br />
‣ For the 71 times the test predicted disease, the test matched the gold<br />
standard 51 times.<br />
‣ For the 179 times the test predicted no disease, the test matched the gold<br />
standard 160 times<br />
For this test, statistically which is most likely<br />
A) to claim that a patient does not have disease when they do<br />
B) to be incorrect when positive for disease<br />
C) To incorrectly claim that a patient has disease when they do not<br />
D) To be incorrect when negative for disease