09.01.2015 Views

Download - Department of Land Resources

Download - Department of Land Resources

Download - Department of Land Resources

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

RFP for ANAND & other Seven DISTRICTS Resurvey project<br />

iii. Accuracy levels required: same as their respective control point<br />

The description <strong>of</strong> the location <strong>of</strong> the control point along with a sketch shall be submitted to<br />

SC&DLR.<br />

Note: In case any village tri-junction has not been marked and monumented by any <strong>of</strong> the<br />

primary or secondary control points or even if it is tertiary control points, then they should be<br />

explicitly monumented as per the parameters mentioned for secondary control points.<br />

(1) The coordinate lists and descriptions <strong>of</strong> the locations shall be submitted to<br />

SC&DLR .The locations and ID s <strong>of</strong> all the control points should be<br />

maintained in GIS Form.<br />

(2) The coordinate list should be supplied both for geodetic system (lat/long)<br />

and Projected system-Universal Traverse Mercator , i.e the UTM projection<br />

<strong>of</strong> the respective area<br />

(3) In case a village tri-junctions has not marked and monumented by primary,<br />

secondary, or tertiary control points, the same should be monumented as per<br />

the parameters.<br />

General Requirements<br />

1. Village boundaries are to be marked.<br />

2. The(X, Y, Z) coordinates for the control points should be given in spherical coordinates<br />

as well as in Cartesian coordinates separately.<br />

3. The (X, Y) coordinates should be in WGS 84.and Z in MSL( Mean Sea Level)<br />

4. The agency should specify the conditions and specification <strong>of</strong> the instruments/system<br />

used to acquire the required accuracy.<br />

5. Some base lines for calibration with monumentation should be formed at selected<br />

locations for maintenance.<br />

6. A sketch for each category <strong>of</strong> control points shall be submitted showing the location <strong>of</strong><br />

control points along with description for easy identification.<br />

7. A district map showing all the Primary, secondary and tertiary control points with<br />

coordinates shall be submitted to the SC&DLR.<br />

2/22/2011<br />

40

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!