GladiATR Base Optics (must select, insert spectrometer model for XX)<br />

P ART N UMBER<br />

026-18XX<br />

D ESCRIPTION<br />

GladiATR Single Reflection ATR Base Optics<br />

Notes: GladiATR Base Optics includes liquids plate, volatiles cover, purge tubes,<br />

purge kit and spectrometer base mount. Please see the <strong>FTIR</strong> instrument code sheet.<br />

GladiATR Crystal Plates (must select 1 or more)<br />

P ART N UMBER<br />

D ESCRIPTION<br />

026-2100 Diamond Crystal Plate<br />

026-2050 Ge Crystal Plate<br />

026-2200 Specular Reflection Plate<br />

Notes: GladiATR Crystal Plates are pre-aligned and pinned-in-place.<br />

Changing crystal plates is easy and fast to optimize sampling results.<br />

GladiATR Pressure Clamp (must select for solid or powdered samples)<br />

P ART N UMBER<br />

D ESCRIPTION<br />

026-3020 High Pressure Clamp<br />

Notes: The High Pressure Clamp is recommended for general applications.<br />

Pressure clamps include a flat tip, a swivel tip and a concave tip.<br />

O RDERING I NFORMATION<br />

GladiATR Temperature Controlled Crystal Plates<br />

P ART N UMBER<br />

D ESCRIPTION<br />

026-4100 Heated Diamond Crystal Plate<br />

026-4050 Heated Ge Crystal Plate<br />

026-4110 Liquid Jacketed Diamond Crystal Plate<br />

026-4150 Liquid Jacketed Ge Crystal Plate<br />

076-1410 Digital Temperature Control Module, PC Control<br />

076-1210 Digital Temperature Control Module<br />

Notes: For heated crystal plates, maximum crystal temperature is 210 °C.<br />

Temperature controller selection is required for heated crystal plates.<br />

Digital temperature controller, PC control includes PIKE TempPRO s<strong>of</strong>tware.<br />

Liquid jacketed crystal plates require customer provided circulator.<br />

GladiATR Sampling Options<br />

Specifications for Resistively Heated GladiATR Plates<br />

Temperature Range: Ambient to 210 °C<br />

Accuracy: +/- 0.5%<br />

Voltage:<br />

Sensor Type:<br />

Controllers<br />

Digital:<br />

Digital PC:<br />

Input Voltage:<br />

Output Voltage:<br />

P ART N UMBER<br />

24 VAC<br />

D ESCRIPTION<br />

3 wire Pt RTD (low drift, high stability)<br />

+/- 0.1% <strong>of</strong> set point<br />

+/- 0.1% <strong>of</strong> set point, graphical setup, up to 3 ramps,<br />

USB interface<br />

110/220 V, switch able<br />

10A/24 VAC<br />

026-5012 Flow-through Attachment<br />

Notes: Flow through attachment is compatible with all crystal <strong>of</strong>ferings.<br />

A TTENUATED T OTAL R EFLECTANCE – L IQUIDS, SOLIDS AND I N -BETWEEN<br />