Untitled
Untitled
Untitled
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
› Mae 65<br />
A5000MA<br />
SUPPORTED INVESTIGATION<br />
Measure of conduttance<br />
A5000MA thermo-flow meter for heat<br />
transmission measurements on site<br />
stands out for utmost accuracy in<br />
data acquisition (24-bit resolution)<br />
combined to the great versatility and<br />
simplicity of use. With the use of four<br />
probes to measure contact temperature<br />
and a flow plate, the instrument<br />
measures the on-site transmission<br />
values of the opaque walls of entire<br />
buildings as set forth by recent laws<br />
on energy saving. The data acquisition<br />
device is equipped with graphic display<br />
for the real time visualization of<br />
the trend of the values acquired, keyboard<br />
with charge-transfer technology<br />
and removable S.D. memory for<br />
storing and following elaboration of<br />
the measurements acquired. The recording<br />
methods can be set using the<br />
software in an easy and quick manner,<br />
to carry out surveys with utmost accuracy<br />
and simplicity. A5000MA thermoflow<br />
meter is envisaged to carry out<br />
medium and long-term surveys and<br />
is suitable to measure environmental<br />
parameters on site and in the laboratory.<br />
The data acquired is downloaded<br />
on PC and elaborated with GT LAB<br />
software (supplied) for the direct calculation<br />
of coefficient K (heat transmission)<br />
and of the parameters linked<br />
to thermal insulation of the building<br />
tested, through the progressive average<br />
method. The instrument complies<br />
with ISO 9869 standard.<br />
Fields of use:<br />
Acquisition of environmental parameters<br />
on existing buildings (prior to restructuring<br />
activities) in order to determine<br />
the actual insulation need<br />
which falls within the parameters<br />
set forth by law, and on new buildings<br />
(after restructuring activities) to<br />
evaluate the quality of the work performed.<br />
SPECIFICATIONS<br />
Acquisition:<br />
• Resolution: 24 bit<br />
• Maximum distortion: 0.0005%<br />
• Number of channels: 5 analogue + 2 digital<br />
(optional)<br />
• Maximum sampling: 1Hz<br />
• Maximum range of inlet signal: 0-2.5V<br />
Recording:<br />
• Recording intervals: from 10 seconds to 12<br />
hours<br />
• Watch: integrated with buffer battery<br />
• Recording support: removable SD memory<br />
up to 2 GB<br />
• Data format: TSV, BMP<br />
• Measurement type: relative or absolute<br />
Thermometers:<br />
• Number: 4<br />
• Temperature range: -40 - +110°C<br />
• Precision: ±0.2°C<br />
Thermo-flow plate:<br />
• Sensitivity: 50μV/Wm2 (typical)<br />
• Temperature range: -30 / +70°C<br />
• Diameter: 80mm<br />
• Thickness: 5mm<br />
• Measured flow: bidirectional<br />
General data:<br />
• Keyboard: 24 charge-transfer buttons<br />
• Display: mono-chromatic graphic LCD 320 x<br />
240 pixel<br />
• Measures display: numeric and graphic<br />
• Power supply: batteries AA type rechargeable<br />
and replaceable (12V – 2.5Ah). Envisaged<br />
for external power supply<br />
• Typical consumption: 40mA monitor off -<br />
90mA monitor on<br />
• Container: anti-crash, in copolymers of polypropylene<br />
• Operating temperature: 0/60°C<br />
• Sizes and weight: L. 270 x H. 120 x P. 246<br />
mm, 3 Kg<br />
mae-srl.it/go/A5000MA