Untitled
Untitled
Untitled
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
› Mae 61<br />
DL-8<br />
SUPPORTED INVESTIGATION<br />
Structural Monitoring<br />
Ambiental Monitoring<br />
Crack monitoring<br />
DL 8 is a compact and affordable data-logger<br />
for structural and environmental<br />
monitoring. The low purchase<br />
and management costs render it ideal<br />
for all monitoring applications which<br />
require flexibility, prompt installation,<br />
and facility to manage the acquired<br />
data, also remotely. The data<br />
acquired by the unit can be indeed<br />
downloaded locally through the USB<br />
interface or remotely through GSM/<br />
GPRS connection (available upon request).<br />
The USB interface allows to<br />
program the parameters and data<br />
acquisition methods of the sensors<br />
connected to the DL-8 unit, through<br />
local connection with a PC or notebook<br />
on which the DL-8 MANAGER<br />
software is installed. DL-8 is ideal in<br />
the structural sector, such as for example<br />
for monitoring holes through<br />
various types of displacement transducers<br />
in buildings and infra-structural<br />
works, and also in the environmental<br />
sector, for monitoring<br />
meteorological parameters (temperature,<br />
humidity) or for the constant<br />
monitoring of levels (reservoirs, basins,<br />
lakes) or capacity measurements<br />
of rivers.<br />
SPECIFICATIONS<br />
Acquisition:<br />
• Resolution: 10 bit<br />
• Number of channels: 8<br />
• Sampling: 0.5Hz<br />
• Maximum range of inlet signal (without<br />
influence): 0-2.5V<br />
• Signals influence: with internal<br />
modules of 4 sensors<br />
Recording:<br />
• Recording intervals: from 2 minutes<br />
to 24 hours<br />
• Measures stored: 770 (circular file)<br />
• Watch: integrated with buffer battery<br />
• Recording support: internal flash<br />
memory<br />
• Data format: TSV<br />
• Measurement type: absolute<br />
• Interfaces: USB, GSM (optional)<br />
General data:<br />
• Measures display: numeric and<br />
graphic (on PC)<br />
• Alarms: with closed contacts and/or<br />
via SMS (only with GSM)<br />
• Alarm thresholds: no. 2 set for each<br />
channel<br />
• Power supply: internal batteries AA<br />
type rechargeable (4.8V – 2.5Ah)<br />
• Typical consumption: 10-30mA (depending<br />
on the sensors connected)<br />
• Average autonomy: 60 days without<br />
GSM option, 30 days with GSM<br />
• Operating temperature: 0-60°C<br />
• Sizes and weight: L190 mm x P110<br />
mm x H60 mm, 0.8Kg<br />
mae-srl.it/go/DL8