› Geo-Electric Explorations<br />

50<br />

A6000SE<br />

SUPPORTED INVESTIGATION<br />

Multi-electrode geoelectrical prospections<br />

V.E.S. Vertical Electric Survey<br />

Measure of self potentiaL<br />

Measure of chargeability<br />

Induced Polarization<br />

Seismic refraction investigation<br />

Seismic riflession investigation<br />

Seismic tomography<br />

Down-hole / Cross-hole<br />

M.A.S.W. / S.A.S.W. / Re.Mi.<br />

Passive seismic acquisition<br />

Seismic vibration monitoring<br />

Nakamura method<br />

SPECIFICATIONS<br />

Electric measures:<br />

Outlet current:<br />

• Automatic regulation (4 steps)<br />

• Maximum intensity: 1.2 A at 50V<br />

• Outlet voltages: ±50V, ±100V, ±250V, ±500V<br />

nominal<br />

• Maximum power: 60W<br />

• Input time: set from 100 ms to 30s<br />

• Measurement precision: ±38μA<br />

Potential measurement:<br />

• Auto range (4 steps)<br />

• Maximum full scale: 50V<br />

• Inlet impedance: 1 MΩ<br />

• Network frequency filter: 50 Hz<br />

• Measurement precision: maximum ±38μV<br />

(within range 0-1.25V), minimum ±1.53mV<br />

(within range 5-50V)<br />

• Noise reduction: with average from 2 to 10<br />

measurements<br />

• Automatic zeroing of self-potential<br />

• Accuracy of the resistivity measured: ±1%<br />

• Chargeability measured on four temporal<br />

windows of overall duration of 1.2 seconds<br />

Electrodes managed:<br />

• 256 with external commutating boxes<br />

Data formats:<br />

• TSV, CSV, DAT<br />

Seismic exploration:<br />

• Converters: 24 bit resolution, sigma- delta<br />

technology<br />

• Dynamic range: 144 dB (theoretical)<br />

• Maximum distortion: +/-0.0010%<br />

• Band width: 2Hz-30KHz<br />

• Common mode rejection: 110 dB at 60 Hz<br />

• Diaphony: -120dB at 20Hz<br />

• Noise threshold of the programmable amplifier:<br />

27nV<br />

• Trigger precision: 1/30 of the sampling time<br />

• Maximum range of inlet signal: +/-5V<br />

• Inlet impedance at 1000 samples/second:<br />

20MΩ<br />

• Amplification levels: 0 dB, 6 dB, 12 dB, 18 dB,<br />

24 dB, 30 dB, 36 dB that can be set singularly<br />

for each channel or for groups of channels<br />

that can be organized freely<br />

• Anti-alias filter: -3dB, 80% of Nyquist frequency,<br />

-80dB<br />

• Pre-trigger time: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,<br />

12, 13, 14, 15, 16, 17, 18, 19, 20, 50, 100, 200,