› Geo-Electric Explorations<br />
50<br />
A6000SE<br />
SUPPORTED INVESTIGATION<br />
Multi-electrode geoelectrical prospections<br />
V.E.S. Vertical Electric Survey<br />
Measure of self potentiaL<br />
Measure of chargeability<br />
Induced Polarization<br />
Seismic refraction investigation<br />
Seismic riflession investigation<br />
Seismic tomography<br />
Down-hole / Cross-hole<br />
M.A.S.W. / S.A.S.W. / Re.Mi.<br />
Passive seismic acquisition<br />
Seismic vibration monitoring<br />
Nakamura method<br />
SPECIFICATIONS<br />
Electric measures:<br />
Outlet current:<br />
• Automatic regulation (4 steps)<br />
• Maximum intensity: 1.2 A at 50V<br />
• Outlet voltages: ±50V, ±100V, ±250V, ±500V<br />
nominal<br />
• Maximum power: 60W<br />
• Input time: set from 100 ms to 30s<br />
• Measurement precision: ±38μA<br />
Potential measurement:<br />
• Auto range (4 steps)<br />
• Maximum full scale: 50V<br />
• Inlet impedance: 1 MΩ<br />
• Network frequency filter: 50 Hz<br />
• Measurement precision: maximum ±38μV<br />
(within range 0-1.25V), minimum ±1.53mV<br />
(within range 5-50V)<br />
• Noise reduction: with average from 2 to 10<br />
measurements<br />
• Automatic zeroing of self-potential<br />
• Accuracy of the resistivity measured: ±1%<br />
• Chargeability measured on four temporal<br />
windows of overall duration of 1.2 seconds<br />
Electrodes managed:<br />
• 256 with external commutating boxes<br />
Data formats:<br />
• TSV, CSV, DAT<br />
Seismic exploration:<br />
• Converters: 24 bit resolution, sigma- delta<br />
technology<br />
• Dynamic range: 144 dB (theoretical)<br />
• Maximum distortion: +/-0.0010%<br />
• Band width: 2Hz-30KHz<br />
• Common mode rejection: 110 dB at 60 Hz<br />
• Diaphony: -120dB at 20Hz<br />
• Noise threshold of the programmable amplifier:<br />
27nV<br />
• Trigger precision: 1/30 of the sampling time<br />
• Maximum range of inlet signal: +/-5V<br />
• Inlet impedance at 1000 samples/second:<br />
20MΩ<br />
• Amplification levels: 0 dB, 6 dB, 12 dB, 18 dB,<br />
24 dB, 30 dB, 36 dB that can be set singularly<br />
for each channel or for groups of channels<br />
that can be organized freely<br />
• Anti-alias filter: -3dB, 80% of Nyquist frequency,<br />
-80dB<br />
• Pre-trigger time: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,<br />
12, 13, 14, 15, 16, 17, 18, 19, 20, 50, 100, 200,