08.01.2015 Views

Untitled

Untitled

Untitled

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

› Mae 37<br />

VIBRAMONITOR<br />

SUPPORTED INVESTIGATION<br />

Passive seismic acquisition<br />

Seismic vibration monitoring<br />

24 bit seismograph studied specifically<br />

for monitoring explosions in mines<br />

or quarries, particularly indicated for<br />

recording seismic vibrations.<br />

The data acquisition methods (timed<br />

or with trigger threshold) are set<br />

through the software easily and quickly.<br />

Equipped with graphic display, keyboard,<br />

memory support of Secure Digital<br />

(S.D.) type and internal battery,<br />

seismograph VIBRAMONITOR is particularly<br />

easy to use also in less favourable<br />

environments and conditions.<br />

mae-srl.it/go/vibramonitor<br />

Thanks to the MAE data acquisition<br />

and conversion card, based on one<br />

single A/D signal converter for each<br />

inlet channel (SST technology), it allows<br />

to obtain the best possible resolution<br />

when acquiring the data for<br />

each single inlet channel and it allows<br />

to record and graphically visualize up<br />

to 4 channels, 3 of which coming from<br />

seismic sensors (with single component<br />

or tridimensional), and the remaining<br />

ones from the sound impact<br />

detector.<br />

SPECIFICATIONS<br />

• Converters: 24 bit resolution, sigma- delta<br />

technology<br />

• Dynamic range: 144 dB (theoretical)<br />

• Maximum distortion: +/-0.0010%<br />

• Band width: 2Hz-30KHz<br />

• Common mode rejection: 110dB at 60Hz<br />

• Diaphony: -120dB at 20Hz<br />

• Noise threshold of the programmable amplifier<br />

27nV<br />

• Maximum range of inlet signal: +/-5V<br />

• Inlet impedance at 1000 samples/second:<br />

20MΩ<br />

• Amplification levels: 0dB, 6dB, 12dB, 18dB,<br />

24dB, 30dB, 36dB that can be set singularly<br />

for each channel<br />

• Anti-alias filter: -3dB, 80% of Nyquist frequency,<br />

-80dB<br />

• Pre-trigger time: from 1% to 50% of the event<br />

duration<br />

• Sampling frequencies 100, 500, 1000, 2000<br />

samples per second; 250c/s in continuous recording<br />

• Sampling intervals: 0.5, 1.0, 2.0, 4.0, 10.0 ms<br />

• Length of the event recorded: from 512 to<br />

21504 samples (215sec. at 100c/s or 10.7sec.<br />

at 2000c/s). Depending on SD capacity in continuous<br />

recording<br />

• Delay: not available<br />

• Channels: 3 seismic + 1 acoustic. Possibility to<br />

use from 1 to the maximum number of channels<br />

installed for each acquisition<br />

• Dynamic range of microphone: 106-142dB<br />

• Test on instruments: only in the laboratory.<br />

Internal self-calibration of the converters prior<br />

to each acquisition<br />

• Digital filters: selected automatically based<br />

on the sampling frequency<br />

• Data storage: on removable SD memory, up<br />

to 2 GB<br />

• Trigger: 10 threshold levels for each channel<br />

(minimum 8mV – max. 5V). Up to 3 coincidence<br />

combinations between channels<br />

• Data format: SEG-2 standard (32-bit long integer),<br />

BIN convertible in ASCII<br />

• Power supply: 12V DC. Internal batteries of<br />

2.5Ah. Average absorption: 150mA. Envisaged<br />

for external power supply<br />

• Environmental conditions: -20/80°C<br />

• Display: mono-chromatic graphic LCD 320 x<br />

240 pixel<br />

• Keyboard: 6 charge-transfer buttons<br />

• Sizes: 23.8 x 6.7 x 14.1 cm<br />

• Weight: 1.4 Kg (cables and sensors excluded)