Untitled
Untitled
Untitled
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
› Seismic Explorations<br />
32<br />
SYSMATRACK<br />
SUPPORTED INVESTIGATION<br />
Seismic refraction investigation<br />
Seismic riflession investigation<br />
Down-hole / Cross-hole<br />
M.A.S.W. / S.A.S.W. / Re.Mi.<br />
24 bit seismograph for seismic prospecting<br />
with refraction, reflection survey,<br />
active and passive MASW (Re.Mi.),<br />
SASW, Down-hole, Cross-hole methods.<br />
The unit is equipped with acquisition<br />
card with 24 bit resolution and<br />
is available in the 12-channel version<br />
that can be extended to 24. Two 24-<br />
pole connectors for the seismic cables<br />
of 12 channels each, the connector for<br />
the starter, the external 12 V supply<br />
and the USB interface to connect the<br />
notebook or PC for the management<br />
of the instrumentation (not supplied)<br />
are located on the front panel. All parameters<br />
relative to the type of seismic<br />
survey that is carried out easily<br />
and quickly, are set up through the<br />
Sysmatrack Manager software, that<br />
can be installed on any PC or notebook<br />
connected to the acquisition unit.<br />
SPECIFICATIONS<br />
• Converters: 24 bit resolution, sigma- delta<br />
technology<br />
• Dynamic range: 144 dB (theoretical)<br />
• Maximum distortion: +/-0.0010%<br />
• Band width: 2Hz-30KHz<br />
• Common mode rejection:<br />
• Diaphony: -120dB at 20 Hz<br />
• Noise threshold of the programmable amplifier<br />
27nV<br />
• Trigger precision: 1/30 of the sampling time<br />
• Maximum range of inlet signal: +/-5V<br />
• Inlet impedance at 1000 samples/second:<br />
20Mohm<br />
• Amplification levels: 0 dB, 6 dB, 12 dB, 18 dB,<br />
24 dB, 30 dB, 36 dB that can be set singularly<br />
for each channel or for groups of channels<br />
that can be organized freely<br />
• Anti-alias filter: -3dB, 80% of Nyquist frequency,<br />
-80dB<br />
• Pre-trigger time: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,<br />
12, 13, 14, 15, 16, 17, 18, 19, 20, 50, 100, 200,<br />
300, 400, 500ms<br />
• Sampling intervals: 1/15, 1/7.5, 1/3.75, 0.5,<br />
1.0, 2.0, 10.0, 20.0 ms<br />
• Number of samples per event: set from 1024<br />
to 43520 with increases of 512<br />
• Delay: not available<br />
• Interfaces available: USB (it requires a control<br />
PC)<br />
• Channels: configurations of 12, 24 channels.<br />
Possibility to use from 1 to the maximum<br />
number of channels installed for each<br />
acquisition<br />
• Test on instruments: only in the laboratory<br />
• Internal self-calibration of the converters<br />
prior to each acquisition<br />
• Digital filters: selected automatically based<br />
on the sampling frequency<br />
• Geophone tests: automatic check to identify<br />
interruptions of cables or broken geophones<br />
or in short circuit. Real time visualization of<br />
the signals coming from the geophones<br />
• Data storage: in the mass memories of the<br />
control PC<br />
• Trigger: positive, negative (optional with<br />
contact lock) with threshold regulated<br />
through a software<br />
• Data format: SEG-2 standard (32-bit long integer)<br />
or ASCII<br />
• Power supply: 12V DC, supplied by a specific<br />
re-chargeable power box. Average absorption:<br />
250mA<br />
• Environmental conditions: -20/80 °C<br />
• Compatible Operative Systems: Windows XP,<br />
Windows Vista, Windows7 of 32bit<br />
mae-srl.it/go/sysmatrack