08.01.2015 Views

Untitled

Untitled

Untitled

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

› Seismic Explorations<br />

32<br />

SYSMATRACK<br />

SUPPORTED INVESTIGATION<br />

Seismic refraction investigation<br />

Seismic riflession investigation<br />

Down-hole / Cross-hole<br />

M.A.S.W. / S.A.S.W. / Re.Mi.<br />

24 bit seismograph for seismic prospecting<br />

with refraction, reflection survey,<br />

active and passive MASW (Re.Mi.),<br />

SASW, Down-hole, Cross-hole methods.<br />

The unit is equipped with acquisition<br />

card with 24 bit resolution and<br />

is available in the 12-channel version<br />

that can be extended to 24. Two 24-<br />

pole connectors for the seismic cables<br />

of 12 channels each, the connector for<br />

the starter, the external 12 V supply<br />

and the USB interface to connect the<br />

notebook or PC for the management<br />

of the instrumentation (not supplied)<br />

are located on the front panel. All parameters<br />

relative to the type of seismic<br />

survey that is carried out easily<br />

and quickly, are set up through the<br />

Sysmatrack Manager software, that<br />

can be installed on any PC or notebook<br />

connected to the acquisition unit.<br />

SPECIFICATIONS<br />

• Converters: 24 bit resolution, sigma- delta<br />

technology<br />

• Dynamic range: 144 dB (theoretical)<br />

• Maximum distortion: +/-0.0010%<br />

• Band width: 2Hz-30KHz<br />

• Common mode rejection:<br />

• Diaphony: -120dB at 20 Hz<br />

• Noise threshold of the programmable amplifier<br />

27nV<br />

• Trigger precision: 1/30 of the sampling time<br />

• Maximum range of inlet signal: +/-5V<br />

• Inlet impedance at 1000 samples/second:<br />

20Mohm<br />

• Amplification levels: 0 dB, 6 dB, 12 dB, 18 dB,<br />

24 dB, 30 dB, 36 dB that can be set singularly<br />

for each channel or for groups of channels<br />

that can be organized freely<br />

• Anti-alias filter: -3dB, 80% of Nyquist frequency,<br />

-80dB<br />

• Pre-trigger time: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,<br />

12, 13, 14, 15, 16, 17, 18, 19, 20, 50, 100, 200,<br />

300, 400, 500ms<br />

• Sampling intervals: 1/15, 1/7.5, 1/3.75, 0.5,<br />

1.0, 2.0, 10.0, 20.0 ms<br />

• Number of samples per event: set from 1024<br />

to 43520 with increases of 512<br />

• Delay: not available<br />

• Interfaces available: USB (it requires a control<br />

PC)<br />

• Channels: configurations of 12, 24 channels.<br />

Possibility to use from 1 to the maximum<br />

number of channels installed for each<br />

acquisition<br />

• Test on instruments: only in the laboratory<br />

• Internal self-calibration of the converters<br />

prior to each acquisition<br />

• Digital filters: selected automatically based<br />

on the sampling frequency<br />

• Geophone tests: automatic check to identify<br />

interruptions of cables or broken geophones<br />

or in short circuit. Real time visualization of<br />

the signals coming from the geophones<br />

• Data storage: in the mass memories of the<br />

control PC<br />

• Trigger: positive, negative (optional with<br />

contact lock) with threshold regulated<br />

through a software<br />

• Data format: SEG-2 standard (32-bit long integer)<br />

or ASCII<br />

• Power supply: 12V DC, supplied by a specific<br />

re-chargeable power box. Average absorption:<br />

250mA<br />

• Environmental conditions: -20/80 °C<br />

• Compatible Operative Systems: Windows XP,<br />

Windows Vista, Windows7 of 32bit<br />

mae-srl.it/go/sysmatrack

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!