› Seismic Explorations<br />
30<br />
A6000S<br />
SUPPORTED INVESTIGATION<br />
Seismic refraction investigation<br />
Seismic riflession investigation<br />
Seismic tomography<br />
Down-hole / Cross-hole<br />
M.A.S.W. / S.A.S.W. / Re.Mi.<br />
Passive seismic acquisition<br />
Seismic vibration monitoring<br />
Nakamura method<br />
SPECIFICATIONS<br />
• Converters: 24 bit resolution, sigma-delta<br />
technology<br />
Dynamic range: 144 dB (theoretical)<br />
•<br />
Maximum distortion: +/-0.0010%<br />
•<br />
Band width: 2Hz-30KHz<br />
•<br />
Common mode rejection: 110 dB at 60 Hz<br />
•<br />
Diaphony: -120dB at 20 Hz<br />
•<br />
Noise threshold of the programmable am-<br />
•<br />
plifier 27nV<br />
• Trigger precision: 1/30 of the sampling time<br />
• Maximum range of inlet signal: +/-5V<br />
• Inlet impedance at 1000 samples/second:<br />
20Mohm<br />
• Amplification levels: 0 dB, 6 dB, 12 dB, 18 dB,<br />
24 dB, 30 dB, 36 dB that can be set singularly<br />
for each channel or for groups of channels<br />
that can be organized freely<br />
• Anti-alias filter: -3dB, 80% of Nyquist frequency,<br />
-80dB<br />
• Pre-trigger time: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,<br />
12, 13, 14, 15, 16, 17, 18, 19, 20, 50, 100, 200,<br />
300, 400, 500ms<br />
• Sampling intervals: 1/30, 1/15, 1/7.5, 1/3.75,<br />
0.5, 1.0, 2.0, 10.0, 20.0 ms<br />
• Number of samples per event: set from 1024<br />
to 43520 with increases of 512<br />
• Interfaces available: LAN, USB, VGA<br />
• Channels: configurations of 12, 24 or 36<br />
channels. Possibility to use from 1 to the<br />
maximum number of channels installed for<br />
each acquisition<br />
• Test on instruments: only in the laboratory<br />
• Internal self-calibration of the converters<br />
prior to each acquisition<br />
• Digital filters: selected automatically based<br />
on the sampling frequency<br />
• Geophone tests: automatic check to identify<br />
interruptions of cables or broken geophones<br />
or in short circuit. Real time visualization of<br />
the signals coming from the geophones<br />
• Data storage: inside an internal FLASH memory<br />
(up to 3GB available) and/or on removable<br />
pen-drive USB<br />
Trigger: positive, negative (optional with<br />
•<br />
contact lock) with threshold regulated<br />
through a software<br />
• Data format: SEG-2 standard (32-bit long integer)<br />
or ASCII<br />
• Power supply: 12V DC, supplied by a specific<br />
re-chargeable power box. Average absorption:<br />
1.5A<br />
• Display: LCD 10.4” with touch-screen, optical<br />
bonding<br />
• Sizes and weight: 40.4x17.4x33 cm, 5 Kg (cables<br />
and sensors excluded)<br />
• Environmental conditions: -20/80°C<br />
• Operative System: Windows Embedded<br />
Standard 2009<br />
• Display optical bounding