› Seismic Explorations<br />

30<br />

A6000S<br />

SUPPORTED INVESTIGATION<br />

Seismic refraction investigation<br />

Seismic riflession investigation<br />

Seismic tomography<br />

Down-hole / Cross-hole<br />

M.A.S.W. / S.A.S.W. / Re.Mi.<br />

Passive seismic acquisition<br />

Seismic vibration monitoring<br />

Nakamura method<br />

SPECIFICATIONS<br />

• Converters: 24 bit resolution, sigma-delta<br />

technology<br />

Dynamic range: 144 dB (theoretical)<br />

•<br />

Maximum distortion: +/-0.0010%<br />

•<br />

Band width: 2Hz-30KHz<br />

•<br />

Common mode rejection: 110 dB at 60 Hz<br />

•<br />

Diaphony: -120dB at 20 Hz<br />

•<br />

Noise threshold of the programmable am-<br />

•<br />

plifier 27nV<br />

• Trigger precision: 1/30 of the sampling time<br />

• Maximum range of inlet signal: +/-5V<br />

• Inlet impedance at 1000 samples/second:<br />

20Mohm<br />

• Amplification levels: 0 dB, 6 dB, 12 dB, 18 dB,<br />

24 dB, 30 dB, 36 dB that can be set singularly<br />

for each channel or for groups of channels<br />

that can be organized freely<br />

• Anti-alias filter: -3dB, 80% of Nyquist frequency,<br />

-80dB<br />

• Pre-trigger time: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,<br />

12, 13, 14, 15, 16, 17, 18, 19, 20, 50, 100, 200,<br />

300, 400, 500ms<br />

• Sampling intervals: 1/30, 1/15, 1/7.5, 1/3.75,<br />

0.5, 1.0, 2.0, 10.0, 20.0 ms<br />

• Number of samples per event: set from 1024<br />

to 43520 with increases of 512<br />

• Interfaces available: LAN, USB, VGA<br />

• Channels: configurations of 12, 24 or 36<br />

channels. Possibility to use from 1 to the<br />

maximum number of channels installed for<br />

each acquisition<br />

• Test on instruments: only in the laboratory<br />

• Internal self-calibration of the converters<br />

prior to each acquisition<br />

• Digital filters: selected automatically based<br />

on the sampling frequency<br />

• Geophone tests: automatic check to identify<br />

interruptions of cables or broken geophones<br />

or in short circuit. Real time visualization of<br />

the signals coming from the geophones<br />

• Data storage: inside an internal FLASH memory<br />

(up to 3GB available) and/or on removable<br />

pen-drive USB<br />

Trigger: positive, negative (optional with<br />

•<br />

contact lock) with threshold regulated<br />

through a software<br />

• Data format: SEG-2 standard (32-bit long integer)<br />

or ASCII<br />

• Power supply: 12V DC, supplied by a specific<br />

re-chargeable power box. Average absorption:<br />

1.5A<br />

• Display: LCD 10.4” with touch-screen, optical<br />

bonding<br />

• Sizes and weight: 40.4x17.4x33 cm, 5 Kg (cables<br />

and sensors excluded)<br />

• Environmental conditions: -20/80°C<br />

• Operative System: Windows Embedded<br />

Standard 2009<br />

• Display optical bounding