INSTALLATION<br />

1<br />

Mark the position on walls for the finished<br />

ceiling height taking into account the thickness<br />

and number of layers of plasterboard to be<br />

used. Fix the GTEC Edge Channels to walls at<br />

600mm maximum centres.<br />

For the location of the GTEC Primary Channels,<br />

mark lines on the ceiling at centres in<br />

accordance with the thickness and number<br />

of layers to be used. See table 1.<br />

2<br />

Attach GTEC Soffit Cleats to the structural soffit<br />

at 1200mm centres along the centre lines for<br />

GTEC Primary Channels.<br />

Cut lengths of GTEC Metal Angle equal to the<br />

vertical distance from the GTEC Soffit Cleats to<br />

the top of the edge channels. Fix GTEC Metal<br />

Angle to the GTEC Soffit Cleats with appropriate<br />

Nut and Bolt.<br />

A GTEC Soffit Cleat is not required for timber joist<br />

floors. Instead, fix GTEC Metal Angles direct to the<br />

sides of timber joist with a minimum overlap of<br />

50mm using a minimum of 2 suitable fixings.<br />

3<br />

Fix GTEC Primary Channel to GTEC Metal Angles<br />

with two GTEC Pan Head Self Drilling screws.<br />

Where necessary, join the GTEC Primary Channel<br />

by overlapping 150mm back to back and fixing<br />

with two appropriate Nuts and Bolts.<br />

64 THE INSTALLATION HANDBOOK 2008