The Installation Handbook - Howarth Timber
The Installation Handbook - Howarth Timber
The Installation Handbook - Howarth Timber
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
4<br />
Cut the GTEC Dryliner Channel RD1 5mm<br />
shorter than the length of the ceiling required<br />
and locate the GTEC Dryliner Channel RD1 into<br />
the GTEC Dryliner Track.<br />
Where required insert mineral wool batts<br />
above the framing ensuring that the mineral<br />
wool forms one continuous lining.<br />
5<br />
Fix plasterboards with the long edges at right<br />
angles to the GTEC Dryliner Channels. Screw-fix<br />
the boards to the GTEC Dryliner Channels<br />
at 230mm maximum centres and 150mm<br />
maximum centres at perimeters and the cut<br />
ends of board.<br />
With two layers of plasterboard, stagger all the<br />
joints between the layers. For the typical single<br />
layer and two-layer plasterboard layouts, see<br />
diagrams overleaf.<br />
Table 1: Maximum framing centres<br />
Board thickness Board length GTEC Dryliner<br />
(mm) (mm) Channel centres (mm)<br />
12.5 2400 400<br />
1800, 2700 450<br />
3600 450<br />
15 and 19 2700 450<br />
other lengths 600<br />
Table 2: Centres for GTEC Joist Connectors and<br />
GTEC SR Brackets<br />
Board thickness<br />
9.5mm plasterboard single layer 600<br />
12.5mm plasterboard single layer 600<br />
15.0mm plasterboard single layer 600<br />
All double layer boarding 600<br />
Maximum (mm)<br />
THE INSTALLATION HANDBOOK 2008<br />
59