Lafarge GTEC Acoustic Homespan System Acoustic Homespan is a lightweight, non-loadbearing metal stud partition system primarily intended for domestic applications. The system is designed to take one layer of 15mm x 900 mm wide Acoustic Homespan Board fixed to each side. It combines purpose-designed sound absorbing boards with technically advanced metal GTEC C Studs to provide at least 40 R W dB sound performance without the requirement for insulation. The boards and studs used have the added benefit of creating a stronger partition than conventional GTEC C Stud partitions and meet heavy duty strength grading classifications when tested in accordance with BS 5234 Part 2 1990. The system also provides 30 minutes fire resistance when tested to BS EN 1364 Part 1 1990. Whilst readily meeting the requirements of Building Regulation Part E, Acoustic Homespan can also be used to match still more demanding specifications. The introduction of a 25mm 19 kg/m 3 mineral wool insulation increases performance to 43 R W dB. Applications • Primarily intended for domestic applications • Lightweight, non-loadbearing Benefits • Achieves 40 R W dB sound rating without insulation • Cost-effective compared with timber stud • Eliminates nail popping and cracking Components GTEC Acoustic Homespan C Stud GTEC Acoustic Homespan Starter Stud GTEC U Track GTEC Deep Flange U Track GTEC Self Tapping screws* GTEC Intumescent Acoustic Sealant GTEC Acoustic Homespan Board GTEC Acoustic Homespan MR Board Lafarge code AHS44/RX AHS50/RX CS44/RX UT45/RX UT52/RX UDT52/B 25DST1000 Acoustic (INTU) ACO 38 (INTU) AC060 (INTU) F1800H F2400H F2700H *See Fixings Selector Installation Guide for details. Dimensions 44mm wide 50mm wide 44mm wide 45mm wide 52mm wide 52mm wide 25mm 0.9 litre 0.38 litre 0.6 litre (new foil refill) 15 x 900 x 1800 15 x 900 x 2400 15 x 900 x 2700 F2400HM 15 x 900 x 2400 40 THE INSTALLATION HANDBOOK 2008
For fixing GTEC plasterboard to timber stud partitions frequently used in timber-frame houses, small restoration projects and home extensions. Partitions: GTEC Drywall Timber Stud
- Page 1 and 2: PLASTERBOARD The Backing of a World
- Page 3 and 4: Introduction
- Page 5 and 6: What are the values of GTEC The GTE
- Page 7 and 8: Environmental Policy Fulfilling our
- Page 9 and 10: The Lafarge GTEC Direct Bond System
- Page 11 and 12: Table 2: Use of GTEC Universal Bond
- Page 13 and 14: 4 Apply vertical dabs at required c
- Page 15 and 16: The Lafarge GTEC Wall Lining System
- Page 17 and 18: STUD Max. Height Guidance Table (m)
- Page 19 and 20: 4 Using a disc cutter, drop-saw or
- Page 21 and 22: The Lafarge GTEC Dryliner System is
- Page 23 and 24: Insulation Existing Wall Insulation
- Page 25 and 26: 4 Cut each GTEC Dryliner Channel RD
- Page 27 and 28: The Lafarge GTEC Metal Stud System
- Page 29 and 30: Table 1: Components for Metal Stud
- Page 31 and 32: 4 Place the ceiling GTEC U Track on
- Page 33 and 34: 10 Form as required, one of the fol
- Page 35 and 36: The Lafarge GTEC Acoustic Homespan
- Page 37 and 38: Skirting Detail A GTEC U Track onto
- Page 39 and 40: 4 Place the ceiling GTEC U Track on
- Page 41: 10 Fix the GTEC Acoustic Homespan b
- Page 45 and 46: GTEC Intumescent Acoustic Sealant a
- Page 47 and 48: The Lafarge GTEC Direct to Timber S
- Page 49 and 50: Single-layer Boarding Noggins Note:
- Page 51 and 52: The Lafarge GTEC Acoustic Floor Sys
- Page 53 and 54: GTEC Metal Angle GTEC Acoustic Floo
- Page 55 and 56: 4 Fix self adhesive GTEC Resilient
- Page 57 and 58: The Lafarge GTEC Dryliner System is
- Page 59 and 60: Upgrading existing timber joist flo
- Page 61 and 62: 4 Cut the GTEC Dryliner Channel RD1
- Page 63 and 64: The Lafarge GTEC Suspended MF Ceili
- Page 65 and 66: GTEC Primary Channel GTEC Connectin
- Page 67 and 68: 4 Secure the GTEC Ceiling Channels
- Page 69 and 70: The Lafarge GTEC T-Bar Corridor Sys
- Page 71 and 72: 60 x 60mm rock mineral wool batt TO
- Page 73 and 74: 3 Position the boards with long edg
- Page 75 and 76: The Lafarge GTEC T-Bar Flat Ceiling
- Page 77 and 78: GTEC T-Bar Primary Main T 60x60mm r
- Page 79 and 80: 4 Fix GTEC T-Bar Cross T TC1200 to
- Page 81 and 82: Lafarge GTEC Taping and Jointing Sy
- Page 83 and 84: Square and Cut Edge Joints External
- Page 85 and 86: 4 Internal Angles When set hard and
- Page 87 and 88: 10 Square Edge Joints When set hard
- Page 89 and 90: Lafarge GTEC Taping and Jointing Sy
- Page 91 and 92: GTEC Cove is a simple and cost effe
Lafarge GTEC<br />
Acoustic<br />
Homespan System<br />
Acoustic Homespan is a lightweight,<br />
non-loadbearing metal stud partition<br />
system primarily intended for domestic<br />
applications. <strong>The</strong> system is designed to<br />
take one layer of 15mm x 900 mm wide<br />
Acoustic Homespan Board fixed to each<br />
side. It combines purpose-designed sound<br />
absorbing boards with technically<br />
advanced metal GTEC C Studs to provide<br />
at least 40 R W dB sound performance<br />
without the requirement for insulation.<br />
<strong>The</strong> boards and studs used have the added<br />
benefit of creating a stronger partition<br />
than conventional GTEC C Stud partitions<br />
and meet heavy duty strength grading<br />
classifications when tested in accordance<br />
with BS 5234 Part 2 1990. <strong>The</strong> system<br />
also provides 30 minutes fire resistance<br />
when tested to BS EN 1364 Part 1 1990.<br />
Whilst readily meeting the requirements<br />
of Building Regulation Part E, Acoustic<br />
Homespan can also be used to match<br />
still more demanding specifications.<br />
<strong>The</strong> introduction of a 25mm 19 kg/m 3<br />
mineral wool insulation increases<br />
performance to 43 R W dB.<br />
Applications<br />
• Primarily intended for domestic applications<br />
• Lightweight, non-loadbearing<br />
Benefits<br />
• Achieves 40 R W dB sound rating<br />
without insulation<br />
• Cost-effective compared with timber stud<br />
• Eliminates nail popping and cracking<br />
Components<br />
GTEC Acoustic<br />
Homespan<br />
C Stud<br />
GTEC Acoustic<br />
Homespan<br />
Starter<br />
Stud<br />
GTEC U Track<br />
GTEC Deep<br />
Flange<br />
U Track<br />
GTEC Self Tapping<br />
screws*<br />
GTEC Intumescent<br />
Acoustic Sealant<br />
GTEC<br />
Acoustic<br />
Homespan<br />
Board<br />
GTEC<br />
Acoustic<br />
Homespan<br />
MR Board<br />
Lafarge<br />
code<br />
AHS44/RX<br />
AHS50/RX<br />
CS44/RX<br />
UT45/RX<br />
UT52/RX<br />
UDT52/B<br />
25DST1000<br />
Acoustic<br />
(INTU)<br />
ACO 38<br />
(INTU)<br />
AC060<br />
(INTU)<br />
F1800H<br />
F2400H<br />
F2700H<br />
*See Fixings Selector <strong>Installation</strong> Guide for details.<br />
Dimensions<br />
44mm wide<br />
50mm wide<br />
44mm wide<br />
45mm wide<br />
52mm wide<br />
52mm wide<br />
25mm<br />
0.9 litre<br />
0.38 litre<br />
0.6 litre<br />
(new foil refill)<br />
15 x 900 x 1800<br />
15 x 900 x 2400<br />
15 x 900 x 2700<br />
F2400HM 15 x 900 x 2400<br />
40 THE INSTALLATION HANDBOOK 2008