Direct Bond (including GTEC Thermal Board) Components Lafarge code Size Lafarge GTEC Direct Bond system is used for attaching plasterboard and GTEC Thermal Board directly onto masonry backgrounds. This method is quick to apply and can be used to correct minor irregularities in the existing background. GTEC Universal Bonding Compound* BOND25 25 kg Applications • Lining new masonry walls for domestic use. • Lining new masonry walls for commercial use. • Lining old masonry walls which have an even background. Benefits • Quick and cost effective to install. • No mechanical fixing is needed with GTEC Standard Board. Good Site Practice • This system must only be used on walls which are free from damp. • GTEC Universal Bonding Compound must harden before jointing, allow 8 hours. • Will only correct minor surface irregularities. • Not suitable for the installation of GTEC Vapour Board, GTEC Moisture Board, GTEC Fire MR Board or GTEC Hydrodeco. GTEC Nailable Plugs* NP60 60mm NP80 80mm NP100 100mm NP120 120mm GTEC Board * For use with all GTEC Thermal Board linings. Preparation various Prepare surfaces as required according to table 1 and select appropriate adhesive. Cut plasterboard 10mm shorter than the floor to ceiling height. Notes: See GTEC Product Selector Installation Guide for details 1. Extremely smooth surfaces may require abrasion prior to PVCA treatment. 2. Surfaces must be free of mould, oil and dust. Contaminated surfaces may require chemical cleaning. Painted surfaces are not suitable for direct bonding; use Lafarge GTEC Dryliner System. 3. Maximum build-up with GTEC Universal Bonding Compound is 25mm. Use Lafarge GTEC Dryliner System if the walls are consistently more than 25mm out of plumb. 12 THE INSTALLATION HANDBOOK 2008
The Lafarge GTEC Wall Lining System is designed to be installed clear of existing walls. Wall Linings: GTEC Independent Wall Lining
- Page 1 and 2: PLASTERBOARD The Backing of a World
- Page 3 and 4: Introduction
- Page 5 and 6: What are the values of GTEC The GTE
- Page 7 and 8: Environmental Policy Fulfilling our
- Page 9 and 10: The Lafarge GTEC Direct Bond System
- Page 11 and 12: Table 2: Use of GTEC Universal Bond
- Page 13: 4 Apply vertical dabs at required c
- Page 17 and 18: STUD Max. Height Guidance Table (m)
- Page 19 and 20: 4 Using a disc cutter, drop-saw or
- Page 21 and 22: The Lafarge GTEC Dryliner System is
- Page 23 and 24: Insulation Existing Wall Insulation
- Page 25 and 26: 4 Cut each GTEC Dryliner Channel RD
- Page 27 and 28: The Lafarge GTEC Metal Stud System
- Page 29 and 30: Table 1: Components for Metal Stud
- Page 31 and 32: 4 Place the ceiling GTEC U Track on
- Page 33 and 34: 10 Form as required, one of the fol
- Page 35 and 36: The Lafarge GTEC Acoustic Homespan
- Page 37 and 38: Skirting Detail A GTEC U Track onto
- Page 39 and 40: 4 Place the ceiling GTEC U Track on
- Page 41 and 42: 10 Fix the GTEC Acoustic Homespan b
- Page 43 and 44: For fixing GTEC plasterboard to tim
- Page 45 and 46: GTEC Intumescent Acoustic Sealant a
- Page 47 and 48: The Lafarge GTEC Direct to Timber S
- Page 49 and 50: Single-layer Boarding Noggins Note:
- Page 51 and 52: The Lafarge GTEC Acoustic Floor Sys
- Page 53 and 54: GTEC Metal Angle GTEC Acoustic Floo
- Page 55 and 56: 4 Fix self adhesive GTEC Resilient
- Page 57 and 58: The Lafarge GTEC Dryliner System is
- Page 59 and 60: Upgrading existing timber joist flo
- Page 61 and 62: 4 Cut the GTEC Dryliner Channel RD1
- Page 63 and 64: The Lafarge GTEC Suspended MF Ceili
Direct Bond (including<br />
GTEC <strong>The</strong>rmal Board)<br />
Components<br />
Lafarge<br />
code<br />
Size<br />
Lafarge GTEC Direct Bond system is<br />
used for attaching plasterboard and<br />
GTEC <strong>The</strong>rmal Board directly onto<br />
masonry backgrounds. This method is<br />
quick to apply and can be used to<br />
correct minor irregularities in the<br />
existing background.<br />
GTEC Universal<br />
Bonding Compound*<br />
BOND25<br />
25 kg<br />
Applications<br />
• Lining new masonry walls for<br />
domestic use.<br />
• Lining new masonry walls for<br />
commercial use.<br />
• Lining old masonry walls which<br />
have an even background.<br />
Benefits<br />
• Quick and cost effective to install.<br />
• No mechanical fixing is needed with<br />
GTEC Standard Board.<br />
Good Site Practice<br />
• This system must only be used on<br />
walls which are free from damp.<br />
• GTEC Universal Bonding Compound must<br />
harden before jointing, allow 8 hours.<br />
• Will only correct minor surface<br />
irregularities.<br />
• Not suitable for the installation of GTEC<br />
Vapour Board, GTEC Moisture Board,<br />
GTEC Fire MR Board or GTEC Hydrodeco.<br />
GTEC Nailable Plugs* NP60 60mm<br />
NP80 80mm<br />
NP100 100mm<br />
NP120 120mm<br />
GTEC Board<br />
* For use with all GTEC <strong>The</strong>rmal Board linings.<br />
Preparation<br />
various<br />
Prepare surfaces as required according to table 1 and<br />
select appropriate adhesive. Cut plasterboard 10mm<br />
shorter than the floor to ceiling height.<br />
Notes:<br />
See GTEC<br />
Product<br />
Selector<br />
<strong>Installation</strong><br />
Guide for<br />
details<br />
1. Extremely smooth surfaces may require abrasion prior<br />
to PVCA treatment.<br />
2. Surfaces must be free of mould, oil and dust.<br />
Contaminated surfaces may require chemical cleaning.<br />
Painted surfaces are not suitable for direct bonding; use<br />
Lafarge GTEC Dryliner System.<br />
3. Maximum build-up with GTEC Universal Bonding<br />
Compound is 25mm. Use Lafarge GTEC Dryliner System if<br />
the walls are consistently more than 25mm out of plumb.<br />
12 THE INSTALLATION HANDBOOK 2008