08.01.2015 Views

THERMOZONE AC 400/ WAC 400 WIRING DIAGRAMS AC401 AND ...

THERMOZONE AC 400/ WAC 400 WIRING DIAGRAMS AC401 AND ...

THERMOZONE AC 400/ WAC 400 WIRING DIAGRAMS AC401 AND ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>THERMOZONE</strong> <strong>AC</strong> <strong>400</strong>/ W<strong>AC</strong> <strong>400</strong><br />

<strong>WIRING</strong> <strong>DIAGRAMS</strong> <strong>AC</strong>401 <strong>AND</strong> <strong>AC</strong>402<br />

Manual 4-stage fan speed regulation with <strong>AC</strong>R304, start/stop with position limit switch AGB304<br />

M ~<br />

c˚ M ~<br />

c˚ M ~<br />

c˚ M ~<br />

c˚<br />

c˚<br />

PTC<br />

<strong>AC</strong>401/<strong>AC</strong>402<br />

L N<br />

L N<br />

L N<br />

L<br />

P N 1 2 3 4 5 6 7 8 9<br />

L1N (L 2 )<br />

230 V~<br />

<strong>AC</strong>401/<strong>AC</strong>402<br />

AGB304,<br />

position limit switch<br />

AGB304<br />

2 6 8<br />

1 3 5 7<br />

<strong>AC</strong>R304<br />

4<br />

3<br />

2<br />

1<br />

0<br />

X<br />

X<br />

X X X<br />

X X<br />

X X<br />

1 3 5 7<br />

<strong>AC</strong>R304,<br />

4-stage regulator<br />

Variable fan speed adjustment with thyristor<br />

2221AG, start/stop with position limit switch<br />

AGB304<br />

Fan speed adjustment in 4 stages with <strong>AC</strong>R304,<br />

start/stop with position limit switch AGB304<br />

<strong>AC</strong>401<br />

P N 1 2 3 4<br />

<strong>AC</strong>401/402<br />

4 5 6 9<br />

<strong>AC</strong>401<br />

P N 1 2 3 4<br />

AGB304,<br />

position limit<br />

switch<br />

<strong>AC</strong>401/402<br />

P N 1 2 3 4 5 6 9<br />

L 1N (L 2 )<br />

230 V~<br />

AGB304,<br />

position limit<br />

switch<br />

L 1 N (L 2 )<br />

230 V~<br />

AGB304<br />

N<br />

~<br />

2221AG<br />

2221AG,<br />

variable fan<br />

speed regulator<br />

AGB304<br />

2 6 8<br />

1 3 5 7<br />

<strong>AC</strong>R304<br />

<strong>AC</strong>R304,<br />

4-stage regulator<br />

Variable fan speed adjustment with thyristor<br />

2221AG<br />

When the motor current exceeds<br />

6 A, a contactor should be<br />

connected parallely with the position<br />

limit switch.<br />

<strong>AC</strong>401<br />

<strong>AC</strong>401<br />

P N 1 2 3 4<br />

P N 1 2 3 4<br />

Maximum current for the variable fan speed<br />

regulator 2221AG is 5A. It can regulate:<br />

2 x <strong>AC</strong>401 or 1 x <strong>AC</strong>402<br />

L 1 N (L 2 )<br />

230 V~<br />

N<br />

~<br />

2221AG<br />

2221AG,<br />

variable fan<br />

speed regulator<br />

Frico AB, Box 102, SE-433 22 Partille • Tel: +46 31-336 86 00 • Fax: +46 31-26 28 60 • mailbox@frico.se • www.frico.se<br />

Design and specifications are subject to change without notice.<br />

105


<strong>THERMOZONE</strong> <strong>AC</strong> <strong>400</strong>/ W<strong>AC</strong> <strong>400</strong><br />

<strong>WIRING</strong> <strong>DIAGRAMS</strong> <strong>AC</strong>412 <strong>AND</strong> <strong>AC</strong>418<br />

Manual 4-stage fan speed regulation with <strong>AC</strong>R304, start/stop with position limit switch AGB304, automatic<br />

2-stage heat regulation with thermostat KRT2800, output selection 0–½–1 output with EV300<br />

M ~<br />

c˚ M ~<br />

c˚ M ~<br />

c˚ M ~<br />

c˚ M ~<br />

c˚<br />

230 V3~<br />

<strong>400</strong> V3~<br />

<strong>AC</strong>412/418<br />

PTC<br />

L N<br />

L N<br />

L N<br />

L<br />

c˚<br />

K1<br />

K2<br />

K3<br />

c˚<br />

P N 1 2 3 4 5 6 7 8 9<br />

10 11 12 13 14 15<br />

L 1 L 2 L 3<br />

<strong>400</strong>V 3~/230V 3~<br />

L 1N (L 2 )<br />

230 V~<br />

AGB304<br />

2 6 8<br />

1 3 5 7<br />

<strong>AC</strong>R304<br />

4<br />

3<br />

2<br />

1<br />

0<br />

X<br />

X<br />

X X X<br />

X X<br />

X X<br />

1 3 5 7<br />

X X<br />

X<br />

O 6 2<br />

5 1<br />

6 2<br />

EV300<br />

1<br />

2<br />

3<br />

Lo<br />

Hi<br />

1<br />

2<br />

3<br />

AGB304,<br />

position limit switch<br />

<strong>AC</strong>R304,<br />

4-stage regulator<br />

EV300,<br />

output selector<br />

Diff (1-4)K<br />

KRT2800<br />

KRT2800,<br />

2-stage<br />

thermostat<br />

Manual 4-stage fan speed regulation with <strong>AC</strong>R304, start/stop with position limit switch AGB304, automatic 2-<br />

stage heat regulation with thermostat RTI2, output selection 0–½–1 output with EV300<br />

<strong>AC</strong>412/418<br />

4 5 6<br />

10 12 13 14 15<br />

L 1 L 2 L 3<br />

<strong>400</strong>V3~/230V3~<br />

<strong>AC</strong>412/418<br />

P N 1 2 3 4 5 6 7<br />

10 12 13 14 15<br />

L 1 L 2 L 3<br />

<strong>AC</strong>412,<strong>AC</strong>418<br />

L 1 N (L 2 )<br />

230 V~<br />

<strong>400</strong>V3~/230V3~<br />

AGB304,<br />

position limit switch<br />

AGB304<br />

2 4 6 8<br />

1 3 5 7<br />

<strong>AC</strong>R304<br />

4<br />

3<br />

2<br />

1<br />

0<br />

X<br />

X<br />

X X X<br />

X X<br />

X X<br />

1 3 5 7<br />

Hi<br />

Lo<br />

1 2 3 4 5 6 7 P N<br />

c˚<br />

RTI2<br />

RTI2,<br />

electronic<br />

2-stage<br />

thermostat<br />

<strong>AC</strong>R304,<br />

4-stage regulator<br />

When the motor current exceeds<br />

6 A, a contactor should be<br />

connected parallely with the position<br />

limit switch.<br />

5 1<br />

6 2<br />

EV300<br />

X X<br />

X<br />

O 6 2<br />

L 1 N (L 2 )<br />

230 V~<br />

EV300,<br />

output selector<br />

106<br />

Frico AB, Box 102, SE-433 22 Partille • Tel: +46 31-336 86 00 • Fax: +46 31-26 28 60 • mailbox@frico.se • www.frico.se<br />

Design and specifications are subject to change without notice.


<strong>THERMOZONE</strong> <strong>AC</strong> <strong>400</strong>/ W<strong>AC</strong> <strong>400</strong><br />

<strong>WIRING</strong> <strong>DIAGRAMS</strong> <strong>AC</strong>412 <strong>AND</strong> <strong>AC</strong>418<br />

High/low fan speed with position limit switch AGB304 and <strong>AC</strong>R3042, automatic 2-stage heat regulation<br />

with thermostat KRT2800, output selection 0–½–1 output with EV300<br />

<strong>AC</strong>412/418<br />

4 5 6<br />

10 12 13 14 15<br />

L 1 L 2 L 3<br />

<strong>400</strong>V3~/230V3~<br />

<strong>AC</strong>412/418<br />

P N 1 2 3 4 5 6 7<br />

10 12 13 14 15<br />

L 1 L 2 L 3<br />

<strong>AC</strong>412,<strong>AC</strong>418<br />

L 1 N (L 2 )<br />

230 V~<br />

<strong>400</strong>V3~/230V3~<br />

AGB304,<br />

position<br />

limit switch<br />

31 32 33 34 35 36 37 38<br />

<strong>AC</strong>R3042<br />

1<br />

2<br />

3<br />

Hi<br />

AGB304<br />

Lo<br />

1<br />

2<br />

3<br />

<strong>AC</strong>R3042,<br />

4-stage<br />

regulator<br />

5 1<br />

Diff (1-4)K<br />

KRT2800<br />

KRT2800,<br />

2-stage<br />

thermostat<br />

X X<br />

X X<br />

X<br />

X X X X<br />

1 2 3 4<br />

6 2<br />

EV300<br />

X X<br />

X<br />

O 6 2<br />

EV300,<br />

output<br />

selector<br />

High/low fan speed with position limit switch AGB304 and <strong>AC</strong>R3042, automatic 2-stage heat regulation<br />

with thermostat RTI2, output selection 0–½–1 output with EV300<br />

<strong>AC</strong>412/418<br />

4 5 6<br />

10 12 13 14 15<br />

L 1 L 2 L 3<br />

<strong>400</strong>V3~/230V3~<br />

<strong>AC</strong>412,<strong>AC</strong>418<br />

<strong>AC</strong>412/418<br />

P N 1 2 3 4 5 6 7<br />

L 1 N (L 2 )<br />

230 V~<br />

10 12 13 14 15<br />

L 1 L 2 L 3<br />

<strong>400</strong>V3~/230V3~<br />

RTI2,<br />

electronic<br />

2-stage<br />

thermostat<br />

31 32 33 34 35 36 37 38<br />

<strong>AC</strong>R3042<br />

Hi<br />

Lo<br />

c˚<br />

RTI2<br />

AGB304,<br />

position<br />

limit switch<br />

AGB304<br />

1 2 3 4 5 6 7 P N<br />

L 1 N (L 2 )<br />

230 V~<br />

5 1<br />

<strong>AC</strong>R3042,<br />

4-stage<br />

regulator<br />

X X<br />

X X<br />

X<br />

X X X X<br />

1 2 3 4<br />

6 2<br />

EV300<br />

EV300,<br />

output selector<br />

Frico AB, Box 102, SE-433 22 Partille • Tel: +46 31-336 86 00 • Fax: +46 31-26 28 60 • mailbox@frico.se • www.frico.se<br />

Design and specifications are subject to change without notice.<br />

107


<strong>THERMOZONE</strong> <strong>AC</strong> <strong>400</strong>/ W<strong>AC</strong> <strong>400</strong><br />

<strong>WIRING</strong> <strong>DIAGRAMS</strong> <strong>AC</strong>412 <strong>AND</strong> <strong>AC</strong>418<br />

Outdoor compensated variable fan speed regulation with FRE6, effect limitation with the output selector<br />

EV300 in effect stages 0-1/2-1<br />

<strong>AC</strong>412/418<br />

P N 1 2 3 4 5 6 7 8 9 10 12 13 14 15 L 1 L 2 L 3<br />

<strong>400</strong>V3~/230V3~<br />

<strong>AC</strong>412/418<br />

P N 1 2 3 4 5 6 7<br />

8 9<br />

10 12 13 14 15 L 1 L 2 L 3<br />

<strong>AC</strong>412-<strong>AC</strong>418<br />

<strong>400</strong>V3~/230V3~<br />

KRT<br />

c˚<br />

3<br />

2<br />

1<br />

1<br />

2<br />

5<br />

6<br />

FRE6,<br />

digital<br />

variable fan<br />

speed regulator<br />

FRE6<br />

L N N U TK TK 1 2 5 6 101112 21222324<br />

EV300<br />

X X<br />

X<br />

O 6 2<br />

EV300,<br />

output selector<br />

L N 1 2<br />

230 V~<br />

Outdoor<br />

sensor<br />

Room Door contact<br />

thermostat<br />

FRE6 regulates a maximum of 4 x <strong>AC</strong>412 or 2 x<br />

<strong>AC</strong>418<br />

<strong>WIRING</strong> <strong>DIAGRAMS</strong> W<strong>AC</strong>401, W<strong>AC</strong>401V, W<strong>AC</strong>402 <strong>AND</strong> W<strong>AC</strong>402V<br />

Outdoor compensated variable fan speed regulation with FRE6<br />

SD20, actuator,<br />

on/off, 230V~<br />

TRV/TVV<br />

20/25<br />

SD20<br />

TRV/TVV<br />

c˚<br />

KRT<br />

3<br />

2<br />

1<br />

W<strong>AC</strong>401-<br />

W<strong>AC</strong>402V<br />

W<strong>AC</strong>401-<br />

W<strong>AC</strong>402V<br />

P N 1 2 3 4 5 6 9<br />

P N 1 2 3 4 5 6 9<br />

FRE6<br />

L N N U TK TK 1 2 5 6 101112 21222324<br />

W<strong>AC</strong>401(V)/402(V)<br />

FRE6 regulates a maximum of 4 x<br />

W<strong>AC</strong>401(V) or 2 x W<strong>AC</strong>402(V)<br />

230 V~<br />

FRE6,<br />

digital<br />

variable fan<br />

speed regulator<br />

Outdoor<br />

sensor<br />

Room<br />

thermostat<br />

Door contact<br />

108<br />

Frico AB, Box 102, SE-433 22 Partille • Tel: +46 31-336 86 00 • Fax: +46 31-26 28 60 • mailbox@frico.se • www.frico.se<br />

Design and specifications are subject to change without notice.


<strong>THERMOZONE</strong> <strong>AC</strong> <strong>400</strong>/ W<strong>AC</strong> <strong>400</strong><br />

<strong>WIRING</strong> <strong>DIAGRAMS</strong> W<strong>AC</strong>401, W<strong>AC</strong>401V, W<strong>AC</strong>402, W<strong>AC</strong>402V<br />

Manual 4-stage fan speed regulation with <strong>AC</strong>R304, start/stop with position limit switch AGB304, automatic<br />

heat regulation with thermostat RTE/KRT, actuator SD20 and valve TVV20/25<br />

SD20, actuator,<br />

on/off, 230V~<br />

For variable fan speed<br />

control, see wiring<br />

diagrams on page 105.<br />

M ~<br />

c˚ M ~<br />

c˚ M ~<br />

c˚ M ~<br />

c˚ M ~<br />

c˚<br />

PTC<br />

W<strong>AC</strong>401(V)/402(V)<br />

TRV/TVV<br />

20/25<br />

L N<br />

L N<br />

L N<br />

L<br />

SD20<br />

RTE102,<br />

electronic<br />

thermostat<br />

TRV/TVV<br />

1<br />

2<br />

3<br />

4<br />

5<br />

P N 1 2 3 4 5 6 7 8 9<br />

W<strong>AC</strong>401-W<strong>AC</strong>402V<br />

AGB304,<br />

position limit<br />

switch<br />

KRT1900<br />

capillary tube<br />

thermostat<br />

RTE<br />

1<br />

2<br />

3<br />

KRT1900<br />

L 1 N (L 2 )<br />

230 V~<br />

AGB304<br />

2 6 8<br />

1 3 5 7<br />

<strong>AC</strong>R304<br />

4<br />

3<br />

2<br />

1<br />

0<br />

X<br />

X<br />

X X X<br />

X X<br />

X X<br />

1 3 5 7<br />

<strong>AC</strong>R304,<br />

4-stage regulator<br />

High/low fan speed with position limit switch AGB304 and <strong>AC</strong>R3042, automatic heat regulation with<br />

thermostat RTE/KRT, actuator SD20 and valve TVV20/25<br />

SD20, actuator,<br />

on/off, 230V~<br />

SD20<br />

W<strong>AC</strong>401-W<strong>AC</strong>402V<br />

4 5 6 9<br />

TRV/TVV<br />

20/25<br />

TRV/TVV<br />

1<br />

2<br />

3<br />

4<br />

5<br />

W<strong>AC</strong>401-<br />

W<strong>AC</strong>402V<br />

P N 1 2 3 4 5 6 9<br />

W<strong>AC</strong>401(V)/402(V)<br />

RTE102<br />

L 1 N (L 2)<br />

230 V~<br />

RTE102,<br />

electronic<br />

thermostat<br />

1<br />

2<br />

3<br />

KRT1900<br />

AGB304<br />

31 32 33 34 35 36 37 38<br />

<strong>AC</strong>R3042<br />

<strong>AC</strong>R3042,<br />

4-stage regulator<br />

KRT1900,<br />

capillary<br />

tube<br />

thermostat<br />

AGB304,<br />

position limit<br />

switch<br />

X X<br />

X X<br />

X<br />

X X X X<br />

1 2 3 4<br />

Frico AB, Box 102, SE-433 22 Partille • Tel: +46 31-336 86 00 • Fax: +46 31-26 28 60 • mailbox@frico.se • www.frico.se<br />

Design and specifications are subject to change without notice.<br />

109

Hooray! Your file is uploaded and ready to be published.