Section 5. Measurement and Control Peripherals<br />

In other applications it may be desirable to simply switch power to a device<br />

without going through a relay. FIGURE. Power Switching without Relay (p. 51)<br />

illustrates a circuit for switching external power to a device without using a<br />

relay. If the peripheral to be powered draws in excess of 75 mA at room<br />

temperature (limit of the 2N2907A medium power transistor), the use of a relay<br />

is required.<br />

Figure 34: Relay Driver Circuit with Relay<br />

Figure 35: Power Switching without Relay<br />

5.2 Other Peripherals<br />

5.2.1 TIMs<br />

Terminal Input Modules (TIMs) are devices that provide simple measurement<br />

support circuits in a convenient package. TIMs include voltage dividers for<br />

cutting the output voltage of sensors to voltage levels compatible with the<br />

<strong>CR200</strong>(X), modules for completion of resistive bridges, and shunt modules for<br />

measurement of analog current sensors.<br />