Section 1. Introduction<br />

Table 1. <strong>CR200</strong> series <strong>Dataloggers</strong> with Built-In Radio<br />

Model Frequency Where Used<br />

CR206X<br />

CR206 (retired)<br />

CR205 (retired)<br />

CR211X<br />

CR211 (retired)<br />

CR210 (retired)<br />

910 to 918 MHz U.S./Canada<br />

920 to 928 MHz Australia/Israel<br />

CR216X<br />

CR216 (retired)<br />

CR215 (retired)<br />

2.450 to 2.482<br />

GHz<br />

Worldwide<br />

Caution No product using the 24XStream radio, including CR216X, will<br />

be available for sale in Europe after 1/1/2015 due to changes in EU<br />

legislation. Consequently, purchase of the CR216X is not recommended<br />

for use in Europe in new networks that may require future expansion.<br />

The CR295X and CR295 (retired) GOES <strong>Dataloggers</strong> include an additional<br />

9-pin serial port that allow communications with a TX320, the retired TX312, or<br />

the retired SAT HDR GOES satellite transmitter. While the CR295 required a<br />

special operating system, the CR295X does not.<br />

Note: Throughout this manual <strong>CR200</strong>(X) will be used to refer to all of the<br />

different models of datalogger in the <strong>CR200</strong>-series and <strong>CR200</strong>X-series. In the<br />

cases where information applies only to a specific model or series of datalogger,<br />

that will be clearly specified.<br />

The <strong>CR200</strong>(X)-series dataloggers have the following enhanced features as<br />

compared to the <strong>CR200</strong>-series dataloggers:<br />

1. 128 Public variables can be used (<strong>CR200</strong>-series had 48).<br />

2. 8 Data Tables can be declared (<strong>CR200</strong>-series had 4).<br />

3. Compiled CRBasic program can be two times larger than for <strong>CR200</strong>-<br />

series.<br />

4. All <strong>CR200</strong>(X)-series CRBasic instructions are supported in a single<br />

operating system. See CRBasic and CRBasic Help for a list of<br />

available instructions. No new instructions have been added. If new<br />

instructions are added in the future, they will apply only to the<br />

<strong>CR200</strong>(X)-series dataloggers.<br />