Technical Data<br />

Mains chokes, motor chokes<br />

15/59<br />

http://catalog.moeller.net<br />

<strong>Moeller</strong> HPL0211-2007/2008<br />

DEX-LN, DEX-LM3<br />

Mains chokes DEX-LN1-… Mains choke DEX-LN3-… Motor chokes DEX-LM3-…<br />

General<br />

Standards<br />

IEC/EN 61558-2-20-2000, VDE 0570 Part 2-20/04-2001, UL, CSA<br />

Operating temperature °C –25…+40, up to 70 with current reduction (see notes)<br />

Storage temperature °C –25…+85 –25…+85 –25…+85<br />

Shock resistance 11 ms 2 /15 g, 3 impacts 11 ms 2 /15 g, 3 impacts 11 ms 2 /15 g, 3 impacts<br />

Vibration resistance g 1 (at 0…150 Hz) 1 (at 0…150 Hz) 1 (at 0…150 Hz)<br />

Vibration 0.35 mm at 10…55 Hz 0.35 mm at 10…55 Hz 0.35 mm at 10…55 Hz<br />

Pollution degree 1 (VDE 0160) 1 (VDE 0160) 1 (VDE 0160)<br />

Altitude m 0 to 1000 above sea level, up to 5000 with current derating (see notes)<br />

Mounting position<br />

Standing vertically, suspended horizontally<br />

Free surrounding areas < 50 < 50 < 50<br />

Degree of protection (terminals) IP20 IP20 up to 40 A<br />

IP 00 from 50 A<br />

Rated duty factor % <strong>DF</strong> 100 100 100<br />

IP20 up to 50 A<br />

IP20 from 63 A<br />

<strong>Frequency</strong> <strong>inverters</strong><br />

<strong>Vector</strong> <strong>frequency</strong> <strong>inverters</strong><br />

Overload cycle 1.5 x I e for 60 s every 600 s 1.5 x I e for 60 s every 600 s 1.5 x I e for 60 s every 600 s (< 24 A)<br />

1.2 x I e for 60 s every 600 s (> 24 A)<br />

Weight kg 0.7 1.5 1.5<br />

Electrical data<br />

Rated voltage U e V AC 230 400 400<br />

Max. supply voltage U L V AC 260 g 0 % 550 g 0 % 750 g 0 %<br />

Operating <strong>frequency</strong> Hz 50/60 50/60 0…200<br />

Insulation class B B B (100 A) F (150 A)<br />

Electrical connection<br />

Terminations K K (40 A) K (50 A)<br />

Connection lugs – K (50 A) K (63 A)<br />

PE stud K K K<br />

Notes 1) The following applies for the installation altitude: Derating with respect to the rated current I e :<br />

I<br />

I e<br />

1.0<br />

0.9<br />

0.8<br />

0.7<br />

0.6<br />

0.5<br />

0 1000 2000 3000 4000<br />

5000<br />

h [m]<br />

For <strong>Moeller</strong> Electric Sales and Support call KMparts.com (866) 595-9616