For <strong>Moeller</strong> Electric Sales and Support call KMparts.com (866) 595-9616<br />

15/56<br />

Technical Data<br />

Radio interference suppression filters<br />

Technical Data<br />

Radio interference suppression filter<br />

15/57<br />

DE6-LZ3...<br />

<strong>Moeller</strong> HPL0211-2007/2008<br />

http://catalog.moeller.net<br />

http://catalog.moeller.net<br />

<strong>Moeller</strong> HPL0211-2007/2008<br />

DE6-LZ3...<br />

DE6-LZ3-013-V4 DE6-LZ3-032-V4 DE6-LZ3-064-V4 DE6-LZ3-080-V4 DE6-LZ3-115-V4 DE6-LZ3-125-V4 DE6-LZ3-150-V4 DE6-LZ3-220-V4 DE6-LZ3-260-V4<br />

<strong>Frequency</strong> <strong>inverters</strong><br />

<strong>Vector</strong> <strong>frequency</strong> <strong>inverters</strong><br />

General<br />

Standards EN 50178, IEC 61800-3, EN 61800-3 incl. A11 EN 50178, IEC 61800-3, EN 61800-3 incl. A11<br />

Environmental conditions<br />

Operating temperature °C –25…+85 –25…+85 –25…+85 –25…+85 –25…+85 –25…+85 –25…+85 – –25…+85<br />

Altitude m 0…1000 a.s.l., derating above 1000: e…2 %/1000 m 0…1000 a.s.l., derating above 1000: e…2 %/1000 m<br />

Mounting position As required, vertically suspended preferred As required, vertically suspended preferred<br />

Free surrounding areas In connection area (cable, terminals): 100 mm In connection area (cable, terminals): 100 mm<br />

Humidity class C C C C C C C C C<br />

Climatic class (IEC) – – – – – –<br />

Protection type IP20 (terminal) IP20 (terminal)<br />

Dimensions (W x H x D) mm 143 x 255 x 29 203 x 260 x 43 244 x 390 x 45 60 x 400 x 87 70 x 440 x 110 70 x 440 x 110 130 x 525 x 94 130 x 525 x 94 142 x 620 x 116<br />

Weight kg 1.4 2.5 4.5 4.3 6.4 6.7 8.8 9.3 13.7<br />

Electrical data<br />

Test voltage in V DC, 2 s<br />

Phase/neutral pole V 2064 2064 2064 2064 2064 2064 2064 2064 2064<br />

Phase/PE V 2064 2064 2064 2064 2064 2064 2064 2064 2064<br />

Leakage current<br />

Max. leakage current in operation mA 30 30 30 30 30 30 30 30 30<br />

Max. leakage current PE and 2 external conductors<br />

mA 180 280 550 690 750 750 380 380 600<br />

disconnected<br />

Rated operating voltage V AC 400 400 400 400 400 400 400 400 400<br />

Rated voltage e V 3 AC 342…528 V g 0 % 3 AC 342…528 V g 0 % 3 AC 342…528 V g 0 % 3 AC 342…528 V g 0 % 3 AC 342…528 V g 0 % 3 AC 342…528 V g 0 % 3 AC 342…528 V g 0 % 3 AC 342…528 V g 0 % 3 AC 342…528 V g 0 %<br />

Supply <strong>frequency</strong> Hz 50/60 (47 -0 %…63 +0 %) 50/60 (47 -0 %…63 +0 %)<br />

Rated operational current<br />

i = 1-phase, 230 V AC A – – – – – – – – –<br />

i = 3-phase, 400 V AC A 13 32 64 80 115 125 150 220 260<br />

Permissible overcurrent 150 % for 10 minutes 150 % for 10 minutes 150 % for 10 minutes 150 % for 10 minutes 150 % for 10 minutes 150 % for 10 minutes 150 % for 10 minutes 150 % for 10 minutes 150 % for 10 minutes<br />

<strong>Frequency</strong> <strong>inverters</strong><br />

<strong>Vector</strong> <strong>frequency</strong> <strong>inverters</strong><br />

Heat dissipation with rated operational current e W 12 14 36 32 38 45 40 60 50<br />

Terminal capacities<br />

Solid mm 2 4 10 25 35 50 50 95 95 95<br />

flexible mm 2 4 6 16 25 50 50 95 95 95<br />

Cables to <strong>frequency</strong> inverter mm 2 3 x 2.5 3 x 6 3 x 16 3 x 16 3 x 35 3 x 35 3 x 50 3 x 70 3 x 95<br />

AWG<br />

PE stud M5 M5 M8 M8 M10 M10 M10 M10 M12<br />

Notes<br />

1) All rating data is based on an ambient temperature of +40°C.<br />

I B<br />

I N<br />

1.2<br />

1.0<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

0<br />

0<br />

20 40 60 80 100<br />