For <strong>Moeller</strong> Electric Sales and Support call KMparts.com (866) 595-9616<br />

15/52<br />

Technical Data<br />

<strong>Vector</strong> <strong>frequency</strong> <strong>inverters</strong><br />

<strong>DV</strong>6<br />

<strong>Moeller</strong> HPL0211-2007/2008<br />

http://catalog.moeller.net<br />

http://catalog.moeller.net<br />

<strong>Moeller</strong> HPL0211-2007/2008<br />

Technical Data<br />

<strong>Vector</strong> <strong>frequency</strong> <strong>inverters</strong><br />

<strong>DV</strong>6<br />

15/53<br />

<strong>DV</strong>6-340-075 <strong>DV</strong>6-340-1K5 <strong>DV</strong>6-340-2K2 <strong>DV</strong>6-340-4K0 <strong>DV</strong>6-340-5K5 <strong>DV</strong>6-340-7K5 <strong>DV</strong>6-340-11K <strong>DV</strong>6-340-15K <strong>DV</strong>6-340-18K5<br />

<strong>Frequency</strong> <strong>inverters</strong><br />

<strong>Vector</strong> <strong>frequency</strong> <strong>inverters</strong><br />

Control circuit<br />

Relay 1 x changeover contact, 230 V AC/0.2 A inductive load/2.5 A resistive load or 24<br />

1 x changeover contact, 230 V AC/0.2 A inductive load/2.5 A resistive load or 24 V DC/0.7 A inductive load/3 A resistive load<br />

V DC/0.7 A inductive load/3 A resistive load<br />

Serial interface RS 422, RS 485 RS 422, RS 485 RS 422, RS 485 RS 422, RS 485 RS 422, RS 485 RS 422, RS 485 RS 422, RS 485 RS 422, RS 485 RS 422, RS 485<br />

Control voltage<br />

Output setpoint voltage V +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mA +10 DC, 20 mA<br />

Output control voltage V +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA +24 DC, 100 mA<br />

Parameterization<br />

3 parameter sets (online/offline parameterization), parameter protection<br />

3 parameter sets (online/offline parameterization), parameter protection (programmable)<br />

(programmable)<br />

Inputs<br />

Thermistor input 1 x PTC thermistor, temperature switch 1 x PTC thermistor, temperature switch<br />

Clockwise rotating field enable (FWD) 1 x +24 V DC (input impedance 4.7 kO) 1 x +24 V DC (input impedance 4.7 kO)<br />

digital (parameters can be defined) 8 x +24 V DC (input impedance 4.7 kO) 8 x +24 V DC (input impedance 4.7 kO)<br />

analog, 12 bit resolution Amount 3 x 0 – +10 V DC, g10 V DC (input impedance 10 kO), 4…20 mA (load<br />

3 x 0 – +10 V DC, g10 V DC (input impedance 10 kO), 4…20 mA (load impedance 100 O)<br />

impedance 100 O)<br />

Outputs<br />

Digital 5 x 24 V DC transistor (open-collector, configurable) 5 x 24 V DC transistor (open-collector, configurable)<br />

analog (parameters can be defined), 8 bit<br />

3 x 0…+10 V DC (max. 2 mA), 4…20 mA (max. load impedance 250 O) 3 x 0…+10 V DC (max. 2 mA), 4…20 mA (max. load impedance 250 O)<br />

resolution<br />

PWM (parameters can be defined) 1 x 0…10 V, max. 1.2 mA 1 x 0…10 V, max. 1.2 mA<br />

Terminal capacities<br />

Cable lengths<br />

Relay connection<br />

Control circuit<br />

mm 2 1.5 2.5 2.5 2.5 2.5 4 6 10 16<br />

AWG 20 18 16 14 12 10 8 6 6<br />

mm 2 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5<br />

AWG 26…16 26…16 26…16 26…16 26…16 26…16 26…16 26…16 26…16<br />

mm 2 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5 0.14…1.5<br />

AWG 26…16 26…16 26…16 26…16 26…16 26…16 26…16 26…16 26…16<br />

<strong>Frequency</strong> <strong>inverters</strong><br />

<strong>Vector</strong> <strong>frequency</strong> <strong>inverters</strong><br />

Notes<br />

1) If the <strong>frequency</strong> inverter is to be installed in a control panel, enclosure or similar<br />

installation, the prevalent ambient within these enclosuresor control panels is<br />

considered to be the ambient temperature a .<br />

All rating data of the power section are based on a switching <strong>frequency</strong> of 5<br />

kHz (default setting) and an ambient temperature of +40 °C, with operation of<br />

a four pole three-phase asynchronous motor.