For <strong>Moeller</strong> Electric Sales and Support call KMparts.com (866) 595-9616<br />

15/20<br />

Engineering<br />

Connection example<br />

<strong>DF</strong>6<br />

<strong>Moeller</strong> HPL0211-2007/2008<br />

http://catalog.moeller.net<br />

<strong>Frequency</strong> <strong>inverters</strong><br />

<strong>Vector</strong> <strong>frequency</strong> <strong>inverters</strong><br />

Block diagram <strong>DF</strong>6<br />

In their default configuration, the <strong>DF</strong>6 <strong>frequency</strong> <strong>inverters</strong> can be used at their assigned supply voltage and<br />

motor rating (four-pole, three-phase asynchronous motor) without any parameter changes. Their acceleration<br />

and deceleration times are set to 30 seconds. The control signal inputs and outputs have the following assigned<br />

functions:<br />

+24 V<br />

FWD<br />

REV<br />

FF1<br />

FF2<br />

AT<br />

RST<br />

1 2 3 4 5 FW P24<br />

RJ 45<br />

RS 422<br />

SN<br />

–<br />

+<br />

Terminal 1: RST = Reset<br />

Terminal 2: AT = change over to analog input OI<br />

Terminal 3: FF2 = Fixed <strong>frequency</strong> 2<br />

Terminal 4: FF1 = Fixed <strong>frequency</strong> 1<br />

Terminal 5: REV = Anticlockwise rotating field<br />

enable (Reverse)<br />

Terminal FW: FWD = Clockwise rotating field<br />

enable (Forward)<br />

Terminal FM: Output <strong>frequency</strong> (PWM signal)<br />

Terminal AMI: Output <strong>frequency</strong> (analog signal<br />

4...20 mA)<br />

Terminal AM: Output <strong>frequency</strong> (analog signal<br />

0...10 V)<br />

Terminal 11: FA1 = <strong>frequency</strong> reaches set point<br />

Terminals K11-K12: Relay, fault signal (K11-K14 ready<br />

for operation)<br />

Terminal K23-K24: Rela, FA1, reference <strong>frequency</strong><br />

reached<br />

Terminal K33-K34: Relay, RUN, in operation<br />

Note:<br />

Terminal BR*:<br />

Brake resistor, for <strong>DF</strong>6-320-11K,<br />

<strong>DF</strong>6-340-11K and <strong>DF</strong>6-340-15K only<br />

Through the built-in keypad, all parameters and functions<br />

can be adapted to the application.<br />

U V W PE<br />

M<br />

3 ~<br />

RS 485<br />

RP<br />

SN<br />

PLC CM1 TH FM AMI AM H O OI L O2<br />

K23 K24 K33 K34<br />

K11<br />

K12 K14<br />

e<br />

PE<br />

L+<br />

R Br<br />

K2 K3<br />

DC+<br />

K1<br />

DC–<br />

SP<br />

BR*<br />

3 AC 400 V, 50/60 Hz<br />

L1<br />

L2<br />

L3<br />

–<br />

+<br />

–10 V...+10 V<br />

0 V<br />

4...20 mA<br />

0...10 V<br />

+10 V<br />

0...+10 V<br />

4...20 mA<br />

10 V (PWM)<br />

PTC<br />