For <strong>Moeller</strong> Electric Sales and Support call KMparts.com (866) 595-9616<br />

<strong>Frequency</strong> <strong>inverters</strong><br />

<strong>Vector</strong> <strong>frequency</strong> <strong>inverters</strong><br />

15/14<br />

Block diagram <strong>DV</strong>51<br />

Engineering<br />

Connection example<br />

<strong>DV</strong>51<br />

In their default configuration, the <strong>DV</strong>51 vector <strong>frequency</strong> <strong>inverters</strong> can be used at<br />

their assigned supply voltage and motor rating (four-pole, three-phase<br />

asynchronous motor) without any parameter changes. Their acceleration and<br />

deceleration times are set to 15 seconds. The control signal inputs and outputs<br />

have the following assigned functions:<br />

Terminal 1: FWD = Clockwise rotating field enable (Forward)<br />

Terminal 2: REV = Anticlockwise rotating field enable (Reverse)<br />

Terminal 3: FF1 = Fixed <strong>frequency</strong> 1<br />

Terminal 4: FF2 = Fixed <strong>frequency</strong> 2<br />

L<br />

N<br />

PE<br />

1<br />

<strong>Moeller</strong> HPL0211-2007/2008<br />

http://catalog.moeller.net<br />

Terminal 5: RST = Reset, can be configured as thermistor input with<br />

parameter C005.<br />

Terminal 6: 2CH = Second parameter set<br />

Terminal 11: FA1 = <strong>Frequency</strong> arrival, type 1 (output <strong>frequency</strong> actual value<br />

= reference input)<br />

Terminal 12: RUN = Running<br />

Terminals K11- Relay, fault signal (K11-K14 ready for operation)<br />

K12:<br />

Through optional keypad DEX-KEY-..., all parameters and functions can be adapted<br />

to the application.<br />

+24 V<br />

3<br />

2CH<br />

FF2<br />

FF1<br />

REV<br />

L1<br />

L2<br />

L3<br />

PE<br />

L+<br />

–<br />

+<br />

R Br<br />

DC+<br />

DC–<br />

BR<br />

–<br />

+<br />

U<br />

V<br />

W<br />

PE<br />

K12 K14<br />

K11<br />

5 L<br />

AM H O OI L 12 11<br />

*<br />

0 V<br />

0...10 V<br />

+10 V<br />

0...10 V<br />

4...20 mA<br />

0 V<br />

RUN<br />

FA1<br />

FWD<br />

6 4 3 2 1<br />

P24<br />

CM2<br />

RJ 45<br />

ModBus<br />

M<br />

3 ~<br />

e<br />

RST<br />

i<br />

* PNU C005 = 19 (PTC)