GPIO CONNECTORS: GPI 1 – 16, GPI 17 – <strong>32</strong>, GPO 1 – 16, GPO 17 -<br />

<strong>32</strong>; 4 x 37-Pin Female (D37F)<br />

GPI: Opto Isolated Input. GPI source must provide power to turn on<br />

opto-isolator.<br />

GPI Opto-isolator Input:<br />

5V - 12 V input voltage<br />

24V use external resistor = 680 - 820 ohm<br />

20ma MAXIMUM CURRENT<br />

GPO: Relay Contact Closure Output. “Dry” contact closure.<br />

GPO Relay Contacts:<br />

0.5 A @ 125VAC<br />

1.0 A @ 24VDC<br />

1.0 A MAXIMUM CURRENT<br />