Test Case: <strong>OpenFlow</strong> Switch Setup and Functional Test<br />

5. Configure the Number of Interfaces by going to the Devices tab on the<br />

<strong>OpenFlow</strong> window. The number of interfaces should be equal to the number of<br />

emulated NICs of a controller.<br />

Figure 7: Devices tab, <strong>OpenFlow</strong> window<br />

6. Go to the Interface tab of the <strong>OpenFlow</strong> window and assign the Protocol<br />

Interfaces that you created on the Protocol Interface window. This interface is<br />

used for the control-plane (OF Channel). Configure Number of Channels as 1.<br />

Figure 8: Interfaces tab, <strong>OpenFlow</strong> window<br />

Following are some of the important parameters available on the Interface tab of<br />

the <strong>OpenFlow</strong> window:<br />

• Periodic Echo: Used to keep OF Channel session alive<br />

• Mode of Connection: Used to indicate whether <strong>Ixia</strong> port initiates TCP<br />

connection. The available options are Passive and Active. Passive is<br />

selected by default and it indicates that the <strong>Ixia</strong> port will not initiate the<br />

TCP connection. Active indicates that the <strong>Ixia</strong> port will be used to initiate<br />

the TCP connection.<br />

PN 915-2635-01 Rev A December 2012 11