Appendix B. Status Table and Settings<br />

Table 121. Status-Table Fields and Descriptions<br />

Fieldname Description Variable Type Default Range Edit Info Type<br />

CalSeOffSet 19<br />

CalDiffOffset 19<br />

Calibration table of singleended<br />

offset values. Each<br />

integration / range<br />

combination has a singleended<br />

offset associated with<br />

it. These numbers are<br />

updated by the background<br />

slow sequence if needed in<br />

the program.<br />

Calibration table of<br />

differential offset values.<br />

Each integration / range<br />

combination has a<br />

differential offset associated<br />

with it. These numbers are<br />

updated by the background<br />

slow sequence if needed in<br />

the program.<br />

Integer array of 18 close to 0 Calib<br />

Integer array of 18 close to 0 Calib<br />

1 The station name written to the header of data files by the datalogger support software (p. 77) is the<br />

station name entered when the software was set up to communicate with the <strong>CR1000</strong>. In contrast, the<br />

station name set in the Status table (by typing it directly into the field, using the StationName()<br />

instruction, or using the SetStatus() instruction), can be sampled into a data table using data table<br />

access syntax. See the Program Access to Data Tables (p. 148) section for more information.<br />

2 PakBus Addresses 1 to 4094 are valid. Addresses >= 4000 are generally reserved for a PC by the<br />

datalogger support software (p. 77).<br />

3 Watchdog errors are automatically reset upon compiling a new program.<br />

4 Replace the lithium battery if