Appendix B. Status Table and Settings<br />

Table 121. Status-Table Fields and Descriptions<br />

Fieldname Description Variable Type Default Range Edit Info Type<br />

Array of Boolean values<br />

telling if communications are<br />

currently active on the<br />

corresponding port.<br />

CommActiveRS-232<br />

CommActiveME<br />

CommActive 15<br />

CommActiveCOM310<br />

CommActiveSDC7<br />

CommActiveSDC8<br />

CommActiveSDC10<br />

CommActiveSDC11<br />

CommActiveCOM1<br />

CommActiveCOM2<br />

CommActiveCOM3<br />

CommActiveCOM4<br />

Boolean array of 9<br />

False, except<br />

for the active<br />

COM<br />

True or False<br />

Status<br />

Array of values telling the<br />

configuration of comm ports.<br />

Aliased to:<br />

CommConfig 16<br />

CommConfigRS-232<br />

CommConfigME<br />

CommConfigCOM310<br />

CommConfigSDC7<br />

CommConfigSDC8<br />

CommConfigSDC10<br />

CommConfigSDC11<br />

CommConfigCOM1<br />

CommConfigCOM2<br />

CommConfigCOM3<br />

CommConfigCOM4<br />

Integer array of 9<br />

RS-232<br />

through<br />

SDC8<br />

= 4 (Enabled)<br />

COM1,<br />

COM2,<br />

COM3, or<br />

COM4 = 0<br />

(Disabled)<br />

0 = Program<br />

Disabled<br />

4 = Program<br />

Enabled<br />

Ports toggled<br />

through program<br />

control<br />

(SerialOpen /<br />

SerialClose).<br />

RS-232 is<br />

always<br />

hardwareenabled.<br />

Config<br />

Baudrate 17<br />

Array of baud rates for<br />

comms. Aliased to:<br />

BaudrateRS-232<br />

BaudrateME<br />

BaudrateSDC<br />

BaudrateCOM1<br />

BaudrateCOM2<br />

BaudrateCOM3<br />

BaudrateCOM4<br />

Integer array of 9<br />

RS-232=-<br />

115200 ME-<br />

SDC8 =<br />

115200<br />

COM1,<br />

COM2,<br />

COM3, or<br />

COM4 = 0<br />

(Disabled)<br />

0 = Auto<br />

1200<br />

2400<br />

4800<br />

9600<br />

19.2k<br />

38.4k<br />

57.6k<br />

115.2k<br />

Yes, can also<br />

use SerialOut<br />

instruction to<br />

setup.<br />

Config<br />

IsRouter<br />

PakBusNodes (p. 433)<br />

Is the <strong>CR1000</strong> configured to<br />

act as router<br />

Number of nodes<br />

(approximately) that will<br />

exist in the PakBus network.<br />

This value is used to<br />

determine how much<br />

memory to allocate for<br />

networking (see<br />

CommsMemFree(2) (p. 433) ).<br />

Boolean False 0 or 1 Yes Config PB<br />

Integer 50 >=50 Yes Config PB<br />