Appendix B. Status Table and Settings<br />

The <strong>CR1000</strong> Status table contains system operating-status information accessible<br />

via the external keyboard / display (p. 567), DevConfig (p. 92), or datalogger support<br />

software (p. 77). Table Common Uses of the Status Table (p. 527) lists some of the<br />

more common uses of Status-table information. Table Status-Table Fields and<br />

Descriptions (p. 528) is a comprehensive list of Status-table registers with brief<br />

descriptions.<br />

Status-table information is easily viewed in Station Status in the datalogger<br />

support software. However, be aware that information presented in Station<br />

Status is not automatically updated. Click the refresh button each time an update<br />

is desired. Alternatively, use the numeric displays of the Connect screen to show<br />

critical values and have these update automatically, or use DevConfig, which polls<br />

the Status table at regular intervals without use of a refresh button.<br />

Note A lot of communications bandwidth and activity are needed to generate the<br />

Status table, so if the <strong>CR1000</strong> is very tight on time, just getting the Status table<br />

itself repeatedly could push timing over the edge and cause skipped scans.<br />

Through the continued development of the operating system, the Status table has<br />

become quite large. A separate settings table has been introduced to slow the<br />

growth of the Status table. To maintain backward compatibility, settings first<br />

included in the Status table have been retained, but are also included in the<br />

Settings Editor in DevConfig (p. 92).<br />

Table 120. Common Uses of the Status Table<br />

Feature or<br />

Suspect Constituent<br />

Status Field(s)<br />

to Consult<br />

Full Reset of <strong>CR1000</strong> FullMemReset (Enter 98765)<br />

Program Execution<br />

Operating System<br />

Power Supply<br />

SRAM<br />

Telecommunications<br />

BuffDepth<br />

MaxBuffDepth<br />

OSVersion<br />

OSDate<br />

OSSignature<br />

WatchdogErrors<br />

Battery<br />

WatchdogErrors<br />

Low12VCount<br />

Low5VCount<br />

StartUpCode<br />

LithiumBattery<br />

MemorySize<br />

MemoryFree<br />

PakBusAddress<br />

Low5VCount<br />