Section 8. Operation<br />

Figure 111: Configuration and wiring of PakBus LAN<br />

8.5.6.2 LAN Setup<br />

Configure <strong>CR1000</strong>s before connecting them to the LAN:<br />

1. Start Device Configuration Utility (DevConfig). Click on Device Type:<br />

<strong>CR1000</strong>. Follow on-screen instructions to power <strong>CR1000</strong>s and connect them<br />

to the PC. Close other programs that may be using the PC COM port, such as<br />

LoggerNet, PC400, PC200W, HotSync, etc.<br />

2. Click on the Connect button at the lower left.<br />

3. Set <strong>CR1000</strong> settings using DevConfig as outlined in table PakBus-LAN<br />

Example Datalogger-Communications Settings (p. 360). Leave unspecified<br />

settings at default values. Example DevConfig screen captures are shown in<br />

figure DevConfig Deployment | Datalogger Tab (p. 359) through figure<br />

DevConfig Deployment | Advanced Tab (p. 360). If the <strong>CR1000</strong>s are not new,<br />

upgrading the operating system or setting factory defaults before working this<br />

example is advised.<br />