Section 8. Operation<br />

8.5.2.1 Router and Leaf-Node Configuration<br />

o<br />

o<br />

o<br />

Routers can be branch routers. Branch routers only know as neighbors<br />

central routers, routers in route to central routers, and routers one level<br />

outward in the network.<br />

Routers can be central routers. Central routers know the entire network.<br />

A PC running LoggerNet is typically a central router.<br />

Routers can be router-capable dataloggers or communications devices.<br />

The <strong>CR1000</strong> is a leaf node by factory default. It can be configured as a router by<br />

setting IsRouter in its Status table to 1 or True. The network shown in figure<br />

PakBus Network Addressing (p. 352) contains six routers and eight leaf nodes.<br />

Consult the appendix Router and Leaf-Node Hardware for a table of available<br />

PakBus® leaf-node and router devices.<br />

Figure 108: PakBus network addressing<br />

LoggerNet is configured by default as a router and can route datalogger- todatalogger<br />

communications.<br />

Table 84. PakBus Leaf-Node and Router Device Configuration<br />

Network<br />

Device<br />

Description<br />

PakBus<br />

Leaf Node<br />

PakBus<br />

Router<br />

PakBus<br />

Aware<br />

Transparent<br />

CR200X Datalogger •<br />

CR800 Datalogger • •<br />

<strong>CR1000</strong> Datalogger • •<br />

CR3000 Datalogger • •<br />

CR5000 Datalogger • •<br />

LoggerNet Software •<br />

NL100<br />

Serial port<br />

network link<br />

• •<br />

NL115 Peripheral port •<br />