Section 8. Operation<br />

Table 79. File-Control Functions<br />

File-Control Functions<br />

Accessed Through<br />

1 Datalogger support software (p. 77) Program Send command<br />

2 Datalogger support software File Control (p. 454) utility<br />

3 Device Configuration Utility (DevConfig) (p. 92) software<br />

4 <strong>Manual</strong> with CF card (CRD: drive) or <strong>Campbell</strong> <strong>Scientific</strong> mass-storage media (USB: drive). See<br />

Data Storage (p. 332)<br />

5 Automatic with CF card (CRD: drive) or <strong>Campbell</strong> <strong>Scientific</strong> mass-storage media (USB: drive)<br />

and Powerup.ini. See Power-up (p. 343)<br />

6 CRBasic instructions (commands). See Data-Table Declarations (p. 475) and File Management<br />

(p. 515) and CRBasic Editor Help.<br />

7 Datalogger support software Retrieve (p. 454) command<br />

8.3.4.1 File Attributes<br />

A feature of program files is the file attribute. Table <strong>CR1000</strong> File Attributes (p. 342)<br />

lists available file attributes, their functions, and when attributes are typically<br />

used. For example, a program file sent via the support software Program Send<br />

command, runs a) immediately ("run now"), and b) when power is cycled on the<br />

<strong>CR1000</strong> ("run on power-up'). This functionality is invoked because Program<br />

Send sets two <strong>CR1000</strong> file attributes on the program file, i.e., Run Now and Run<br />

on Power-up. When together, Run Now and Run on Power-up are tagged as<br />

Run Always.<br />

Note Activation of the run-on-power-up file can be prevented by holding down<br />

the Del key on the external keyboard / display while the <strong>CR1000</strong> is powering up.<br />

Table 80. <strong>CR1000</strong> File Attributes<br />

Attribute Function Attribute for Programs Sent to <strong>CR1000</strong> with:<br />

Run Always<br />

(run on power-up +<br />

run now)<br />

Run on Power-up<br />

Run Now<br />

Runs now and on<br />

power-up.<br />

Runs only on<br />

power-up<br />

Runs only when<br />

file sent to <strong>CR1000</strong><br />

a) Send (p. 454) 1<br />

b) File Control 2 with Run Now & Run on Power-up<br />

selected.<br />

c) CF card (CRD: drive) or <strong>Campbell</strong> <strong>Scientific</strong><br />

mass-storage media (USB: drive) power-up 3 using<br />

commands 1 & 13 (see table Powerup.ini Commands<br />

(p. 345) ).<br />

a) File Control 2 with Run on Power-up checked.<br />

b) CF card (CRD: drive) or <strong>Campbell</strong> <strong>Scientific</strong><br />

mass-storage media (USB: drive) power-up 3 using<br />

command 2 (see table Powerup.ini Commands (p.<br />

345) ).<br />

a) File Control 2 with Run Now checked.<br />

b) CF card (CRD: drive) or <strong>Campbell</strong> <strong>Scientific</strong><br />

mass-storage media (USB: drive) power-up 3 using<br />

commands 6 & 14 (see TABLE. Powerup.ini<br />

Commands (p. 345) ). However, if CF card (CRD:<br />

drive) or <strong>Campbell</strong> <strong>Scientific</strong> mass-storage media<br />

(USB: drive) is left in, program loads again from CF<br />

card (CRD: drive) or <strong>Campbell</strong> <strong>Scientific</strong> massstorage<br />

media (USB: drive).<br />