Section 7. Installation<br />

• Beacon Interval sets the interval (in seconds) on which the datalogger will<br />

broadcast beacon messages on the port specified by Selected Port.<br />

• Verify Interval specifies the interval (in seconds) at which the datalogger<br />

will expect to have received packets from neighbors on the port specified by<br />

Selected Port. A value of zero with automatically result in one of two<br />

outcomes:<br />

o a five-minute verify interval if the neighbor also has 0 set as the Verify<br />

Interval argument, or<br />

o the verify interval of the neighbor will be adopted if it is non-zero.<br />

• Neighbors List, or perhaps more appropriately thought of as the "allowed<br />

neighbors list", displays the list of addresses that this datalogger expects to<br />

find as neighbors on the port specified by Selected Port. As items are selected<br />

in this list, the values of the Begin and End range controls will change to<br />

reflect the selected range. Multiple lists of neighbors can be added on the<br />

same port.<br />

• Begin and End Range are used to enter a range of addresses that can either<br />

be added to or removed from the neighbors list for the port specified by<br />

Selected Port. As users manipulate these controls, the Add- and Removerange<br />

buttons are enabled or disabled depending on the relative values in the<br />

controls and whether the range is present in or overlaps with the list of<br />

address ranges already set up.<br />

• Add Range will cause the range specified in the Begin and End range to be<br />

added to the list of neighbors to the datalogger on the port specified by<br />

Selected Port. This control is disabled if the end range value is less than the<br />

begin range value.<br />

• Remove Range will remove the range specified by the values of the Begin<br />

and End controls from the list of neighbors to the datalogger on the port<br />

specified by Selected Port. This control is disabled if the range specified is<br />

not present in the list.<br />

• Help is displayed at the bottom of the Deployment tab. When finished,<br />

Apply the settings to the datalogger. A summary message is presented. Save<br />

or Print the settings to archive or to use as a template for another datalogger.<br />

• Cancel causes the datalogger to ignore the changes. Read File provides the<br />

opportunity to load settings saved previously from this or another similar<br />

datalogger. Changes loaded from a file will not be written to the datalogger<br />

until Apply is clicked.<br />