<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> <strong>Central</strong><br />
<strong>Control</strong> <strong>Unit</strong> <strong>EWFS</strong> ® Proceed as follows in order to change the product type:<br />
7.2.1 Product type<br />
■<br />
Change to the product settings menu as described above and select a<br />
channel. The following display is shown:<br />
Product<br />
product type<br />
Conserv. awning<br />
— + | }<br />
TIP<br />
When you have selected the product type and saved it, the<br />
values from the two tables shown at the front are set<br />
automatically. If you have carried out changes to the settings<br />
beforehand, your values are overwritten completely during<br />
saving (this does not apply to the date and time or remote<br />
controls already learned).<br />
■ Change the product type by using the buttons — + and then press the<br />
button | (save). If you want to exit the menu without saving the changes,<br />
press the }button twice consecutively. This completes the process.<br />
You have now changed the product type and together with this setting step the<br />
<strong>Wisotronic</strong> has carried out all the sensible settings for the sun protection product<br />
used. As a rule you do not have to carry out any further settings, unless you wish<br />
to optimize the control behavior further.<br />
7.2.2 Runtimes<br />
The runtime of a sunblind is the time which the sunblind requires in order to move<br />
from one end setting to the other (for example from top to bottom). If a sun<br />
protection product is set as described above, sensible runtime and turn times are<br />
also set for this product in the <strong>Wisotronic</strong>. Normally it is not necessary to<br />
intervene here. This section describes how you can nevertheless carry out these<br />
adjustments.<br />
Experience shows that the runtimes of sunblind products differ. Thus a roller<br />
shutter with 150 cm length required a much shorter runtime than a folding arm<br />
awning with 300 cm extension. These runtimes can be adjusted to the connected<br />
product down to the second at the <strong>Wisotronic</strong>. You can also set separate runtimes<br />
for "UP" and "DOWN" because a sunblind requires more time to move up than to<br />
move down. Note: The runtimes are set to mean values in our works.<br />
932806A0•816757•7974k0•08.10.2004 We reserve the right to carry out improvements 81