04.01.2015 Views

Wisotronic dialog 1-Channel Central Control Unit EWFS - Warema

Wisotronic dialog 1-Channel Central Control Unit EWFS - Warema

Wisotronic dialog 1-Channel Central Control Unit EWFS - Warema

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> <strong>Central</strong><br />

<strong>Control</strong> <strong>Unit</strong> <strong>EWFS</strong> ® ■ Press the button +. The text<br />

CAUTION! is displayed. You now have to press the button + as often<br />

as is required to have read the following text completely: CAUTION!<br />

Resetting the ice alert enables the control<br />

of the channel. Movement commands<br />

could destroy frozen products. The user<br />

is responsible for damage to frozen<br />

products. RESET Yes<br />

Ice alert<br />

man. reset<br />

YES<br />

— + | }<br />

■<br />

Now press the button |(save). The ice alert has now been reset. The text<br />

Ice alert enable is displayed and the sunblind can be operated<br />

again. Then press the } button twice successively. This completes the<br />

process.<br />

CAUTION<br />

The ice alert now remains reset until the conditions for an ice<br />

alert exist again: If the external temperature drops below the<br />

set limit AND rain falls, the ice alert is activated again.<br />

We therefore recommend that you enable the ice alert in due<br />

course, in particular if your sunblind is not observed<br />

constantly (for example in your absence).<br />

6.9.2 Enabling the ice alert<br />

again<br />

An ice alert is saved in the <strong>Wisotronic</strong> for the duration of the ice condition. An<br />

example: Because the external temperature dropped below the freezing point<br />

during the night and freezing rain fell briefly afterwards, the ice alert is triggered,<br />

the sunblind is moved up and operation blocked. When you wanted to operate<br />

your sunblind the next morning, you found the ice alert. Because you wanted to<br />

operate the sunblind nevertheless, you reset the ice alert and have, for example,<br />

moved your external venetian blinds down. In the evening you want to enable the<br />

ice alert again, because the frost still exists. Because the ice condition continues<br />

to exist, the sunblind moves up again immediately after the ice alert has been<br />

enabled!<br />

CAUTION<br />

Therefore first ensure that your sun protection cannot be<br />

damaged by the movement: External venetian blinds and<br />

roller shutters, cassette awnings and conservatory awnings<br />

can be frozen tight in their guide rails. If the ice alert is<br />

enabled nevertheless while frost continues, damage to<br />

property may result! If the sunblind is operated during icing,<br />

all guarantees and liabilities expire!<br />

932806A0•816757•7974k0•08.10.2004 We reserve the right to carry out improvements 67