<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> <strong>Central</strong><br />
<strong>Control</strong> <strong>Unit</strong> <strong>EWFS</strong> ® If the sunblind is to be moved down on Saturdays and Sundays at the same time,<br />
6.5.5 Timer switch Sa - Su<br />
"DOWN"<br />
you can set this switching instant here. The setting range is from 00:01 to 23:59.<br />
If you do not wish to move the sunblind down from Sa. to Su., you can also set<br />
the value "00:00" ( --:--) here. Proceed as follows in order to change the<br />
setting:<br />
■ Change to the timer switch menu as described above. Turn the function dial<br />
until the following display appears:<br />
Timer switch<br />
Sa - Su DOWN<br />
8:00<br />
— + | }<br />
■ Change the setting values by using the buttons — + and then press the<br />
button | (save). If you want to exit the menu without saving the changes,<br />
press the } button twice consecutively. This completes the process.<br />
6.5.6 Slat angle after moving<br />
down<br />
This function only makes sense if you have selected a slat product (external<br />
venetian blind or internal venetian blind) as the product type. After moving down<br />
has been completed by the timer switch, the slats are turned open to the set angle.<br />
You can ensure that the sunblind is turned either to let the light through (horizontal,<br />
setting 0°) or to protect against viewing from the outside (for example<br />
+80°).<br />
The following figure illustrates the setting of the slat angle:<br />
Positive value: Slats are turned outwards<br />
Negative value: Slats are turned inwards<br />
Setting 0°: The slats remain in a horizontal position<br />
Outside<br />
Inside<br />
+80° 0°<br />
-80°<br />
Fig. 6-15:<br />
TIP<br />
Slat angle at external venetian blinds and internal venetian blinds<br />
The product-typical turn time as well as the product-typical<br />
turning angle (refer to Section 7.2.3 to 7.2.5) have to be set<br />
first.<br />