<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> <strong>Central</strong><br />
<strong>Control</strong> <strong>Unit</strong> <strong>EWFS</strong> ® The limit "OFF" specifies the temperature at which the sun control is to be<br />
6.3.7.2 Temperature control<br />
limit "OFF"<br />
disabled. Example: On a cold clear winter day you want the sun to first heat up<br />
your conservatory before the sun protection becomes active. After all, the sun is<br />
the most inexpensive heating source. However, if the sun control is activated at<br />
the same time, this could move the sun protection down before your ideal<br />
temperature has been reached. You can therefore program the control system so<br />
that the sun control is not activated until a certain inside temperature has been<br />
reached. The setting range is from –24°C to 74°C. If you do not want to evaluate<br />
the limit "OFF", you can also set the value "0" (---) here. Proceed as follows in<br />
order to change the setting value:<br />
■ Change to the temperature control menu as described above. Turn the<br />
function dial until the following display appears:<br />
Temperature<br />
limit OFF<br />
22° C<br />
— + | }<br />
■ Change the setting values by using the buttons — + and then press the<br />
button | (save). If you want to exit the menu without saving the changes,<br />
press the } button twice consecutively. This completes the process.<br />
Operating mode:<br />
Enable sun<br />
Move<br />
command<br />
Sun control<br />
Fig. 6-12:<br />
The sun control in the "Enable sun" operating mode: The switch does not close<br />
and the sun control is not enabled until the temperature is reached in the room.<br />
When the room temperature drops below the limit "OFF" again, the switch opens<br />
and the sun control is disabled, the sunblind moves up.<br />
932806A0•816757•7974k0•08.10.2004 We reserve the right to carry out improvements 43